双摄像机获取人体呼吸信号的探讨 被引量:1

Detection of Respiratory Signals Using Two Cameras for 4D-CT
下载PDF
导出
摘要 目的:为4D-CT和图像引导放射治疗提供便宜并方便临床应用的提取人体呼吸信号的方法。方法:用激光点打在人体腹部,2个摄像头同时监控这个激光点。求出激光点的三维坐标。以坐标的任意维度描绘和时间的关系曲线,即呼吸曲线。结果:摄像头采集帧率30帧/s,实际可以达到处理15帧/s的速度,因此可以实时获得呼吸曲线。结论:相比其他呼吸信号提取方式,该方法经济且材料易获取。 Objective: To provide a novel easy respiratory detection method for 4D-CT and Image Guided Radiation Treatment (IGRT). Methods: A laser dot was casted on the abdomen of the subject, and two cameras were used to monitor the dot. Then the 3D coordinates of the dot from the Images was calculated out. By correlating the movement of the dot at any dimension with time, the respiratory signals curve was drawn in another image. Results: The actual frame rate is 15 frames per second, which is enough for recording the motion of respiratory. Conclusion: In contrast to other methods, this method cost less and the facilities are very easy to acquire.
出处 《武汉大学学报(医学版)》 CAS 2007年第3期319-321,F0003,共4页 Medical Journal of Wuhan University
关键词 呼吸信号 4D-CT 肿瘤 放射治疗 Respiration Signal 4D-CT Neoplasms Radiotherapy
  • 相关文献

参考文献9

  • 1Mah D,Hanley J,Rosenzweij,KE,et al.Technical aspects of the deep inspiration.breath-hold technique in the treatment of thoracic cancer[J].Radiat Oncol Biol Phys,2000,48:1 175-1 185.
  • 2Rosenzweig KE,Hanley J.The deep inspiration reath-hold technique in the treatment of inoperable non-small cell lung cancer[J].Radiat Oncol Biol Phys,2000,48:81-87.
  • 3Zhang ZY.A flexible new technique for camera calibration[J].IEEE Trans on Pattern Analysis and Machine Intelligence,2000,22(11):1 330-1 334.
  • 4Chen QS,Weinhous MS,Deibel FS,et al.Fluoroscopic study of tumor motion due to breathing:facilitating precise radiation therapy for lung cancer patients[J].Med Phys,2001,28(9):1 850-1 856.
  • 5Sharp GC,Jiang SB,Shimizu S,et al.Prediction of respiratory tumour motion for real-time image-guided radiotherapy[J].Phys Med Biol,2004,49:425-440.
  • 6Sharp GC,Jiang SB,Shimizu S,et al.Prediction of respiratory tumour motion for real-time image-guided radiotherapy[J].Phys Med Biol,2004,49:425-440.
  • 7ike R,Tinsu P,George TY,et al.Four-dimensional computed tomography:Image formation and clinical protocol[J].Med Phys,2005,32(4):874-889.
  • 8Ford EC,Mageras GS,Yorke E,et al.Respiration-correlated spiral CT:A method of measuring respiratoryinduced anatomic motion for radiation treatment planning[J].Med Phys,2003,30(1):88-97.
  • 9Gikas S,et al.Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system[J].Journal of Applied Clinical Medical Physics,2001,2(4):33-51.

同被引文献16

  • 1王冰,职秦川,张仲选,耿国华,周明全.灰度图像质心快速算法[J].计算机辅助设计与图形学学报,2004,16(10):1360-1365. 被引量:32
  • 2Lu Wei, Parikh PJ, Hubenschmidt JP, et al. A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT [ J ]. Medical Physics, 2006, 33 (8) : 2964 - 2974.
  • 3Wink NM, Panknin C, Solberg TD, et al. Phase versus amplitude sorting of 4D-CT data [ J ]. Journal of Applied Clinical Medical Physics, 2006, 7 ( 1 ) : 77 - 85.
  • 4Low DA, Nystrom M, Kalinin E, et al. A method for the reconstruction of four - dimensional synchronized CT scans acquired during free breathing [ J ]. Medical Physics, 2003, 30 (6) : 1254 - 1263.
  • 5Vedam SS, Keall PJ, Kini VR, et aL Acquiring a four- dimensional computed tomography dataset using an external respiratory signal [ J]. Physical in Medicine and Biology, 2003, 48(1) : 45 -62.
  • 6Keall PJ, Starkschall G, Shukla H, et al. Acquiring 4D thoracic CT scans using a multislice helical method [ J ]. Physical in Medicine and Biology, 2004, 49 (10) :2053 -2067.
  • 7Keall PJ, Kini VR, Vedam SS, et al. Potential radiotherapy improvements with respiratory gating [ J]. Australas Phys Eng Sci Med, 2002, 25(1): 1 -6.
  • 8Mageras GS, Yorke E, Rosenzweig K, et al. Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system [ J ]. Applied Clinical Medical Physics, 2001, 2(4) : 191 -200.
  • 9Lujan AE, Larsen EW, Baher JM, et al. A method for incorporating organ due to breathing into 3D dose calculations [J]. Medical Physics, 1999, 26(5), 715 -720.
  • 10Shi Chengyu, Papanikolaou N. Tracking versus gating in the treatment of moving targets [ J]. European Oncological Disease, 2007, 1(1): 83-87.

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部