期刊文献+

ICP—OES测定人发中微量元素的方法研究 被引量:13

Determination of trace elements in Human Hair by ICP—OES
下载PDF
导出
摘要 采用电感耦合等离子体原子发射光谱(ICP—OES)测定头发中的硒、铅、镉含量,并采用两种不同的前处理方法进行比较。结果表明,湿消化法测定的回收率高,仪器测定硒、铅、镉的最低检测线分别为(μg/L)0.5、1.74、0.20,方法精密度高,相对标准偏差为5.49%~12.1%,符合微量分析的要求,适用于头发中硒、铅、镉含量的测定。 Inductively coupled plasma optical emission spectroscopy was proposed for the determination of selenium, plumbum, cadmium in human hair, and two different preparing methods were compared. The results showed that the recoveries of wet digestion had high recoveries. Under the optimum conditions the detection limits of selenium, plumbum, cadmium are separately(μg/L) 0.5,1.74, 0.20. The method is reliable and highly sensitive. The RSDs ( n = 6 ) are between 5,49 % -- 12.1%. The method was applied to the practical samples with satisfactory results.
出处 《微量元素与健康研究》 CAS 2007年第3期45-46,共2页 Studies of Trace Elements and Health
关键词 ICP-OES 头发 ICP-OES human hair selenium plumbum cadmium
  • 相关文献

参考文献8

二级参考文献23

共引文献44

同被引文献139

引证文献13

二级引证文献313

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部