摘要
阐述了ZF□-126(L)型气体绝缘金属封闭开关设备中断路器所用的绝缘支柱的设计思路及电场计算方法,给出了电场计算结果。从优化电场方面,分析了设计绝缘件时应注意的事项。
The design idea and electric field calculation of insulated supporter used in circuit breaker of ZF□ -126 (L) type gas- insulated metal enclosed breaker were discussed, and showed the results of electric field calculation. Some notices relative to insulated components'design were presented in view of optimizing electric field.
出处
《黑龙江电力》
CAS
2007年第2期94-96,共3页
Heilongjiang Electric Power
关键词
气体绝缘金属封闭开关设备
绝缘支柱
电场强度
gas- insulated metal enclosed breakers
insulated supporter
electric field intensity