Determination of Trace Copper (Ⅱ) in Water Samples by Kinetic-spectrophotometry 被引量:3

Determination of Trace Copper (Ⅱ) in Water Samples by Kinetic-spectrophotometry
下载PDF
导出
摘要 A new kinetic-spectrophotometric method is proposed for the determination of copper (Ⅱ). The method is based on the catalytic effect of copper (Ⅱ) on the oxidation of weak acid brilliant blue dye (RAWL) by hydrogen peroxide. The copper (Ⅱ) can be determined spectrophotometrically by measuring the decrease of absorbance of RAWL at λ = 626 nm using the fix-time method. The optimum reaction conditions are as follows: pH 7.20, buffer solution NaOH-KH2PO4, RAWL (200 mg L-1) 5.00 mL, H2O2 (30%) 0.50 mL, reaction temperature 80℃ and reaction time 20 min. The linear range of this method is between 0 μg L-1 and 12 μg L-1 and the limit of detection is 0.011 μg L-1, the relative standard deviation (RSD) in five replicate determinations for 2 and 8 μg L-1 copper (Ⅱ) are 3.2% and 2.3%, respectively. Twenty ions do not interfere in the determination of copper (Ⅱ). The method has been applied satisfactorily to the determination of copper (Ⅱ) in freshwater samples (tap water and Yellow River water from Lijin, Shandong, China) and seawater samples (from the South China Sea), the recovery rates are 98.0%, 102.5% and 96.0%, respectively. A new kinetic-spectrophotometric method is proposed for the determination of copper ( Ⅱ ). The method is based on the catalytic effect of copper ( Ⅱ ) on the oxidation of weak acid brilliant blue dye (RAWL) by hydrogen peroxide. The copper ( Ⅱ ) can be determined spectrophotometrically by measuring the decrease of absorbance of RAWL at λ = 626 nm using the fix-time method. The optimum reaction conditions are as follows: pH 7.20, buffer solution NaOH-KH2PO4, RAWL (200 mgL-1) 5.00 mL, H2O2 (30%) 0.50 mL, reaction temperature 80 ?? and reaction time 20 min. The linear range of this method is between 0 μg L^-1 and 12 μg L^-1 and the limit of detection is 0.011 μg L-1, the relative standard deviation (RSD) in five replicate determinations for 2 and 8 μg L-1 copper ( Ⅱ ) are 3.2% and 2.3%, respectively. Twenty ions do not interfere in the determination of copper ( Ⅱ ). The method has been applied satisfactorily to the determination of copper ( Ⅱ ) in freshwater samples (tap water and Yellow River water from Lijin, Shandong, China) and seawater samples (from the South China Sea), the recovery rates are 98.0%, 102.5% and 96.0%, respectively.
出处 《Journal of Ocean University of China》 SCIE CAS 2007年第2期143-146,共4页 中国海洋大学学报(英文版)
关键词 COPPER kinetic-spectrophotometry catalytic effect weak acid brilliant blue dye (RAWL) 海水水样 痕量铜 分析方法 动态分光光度法
  • 相关文献

参考文献2

二级参考文献10

共引文献26

同被引文献25

  • 1孙登明,李勇.催化动力学光度法间接测定痕量镍[J].稀有金属,2004,28(5):938-941. 被引量:15
  • 2郭振良,杨迎霞.胭脂红褪色光度法测定锌镍合金镀液中的镍含量[J].电镀与涂饰,2004,23(6):25-27. 被引量:2
  • 3谢建鹰,程国平,陆伟峰.阻抑动力学光度法测定痕量铜[J].分析试验室,2007,26(2):37-39. 被引量:6
  • 4GHOLIVAND M B, ROMIANI A A. Application of adsorptive stripping voltammetry to the simultaneous determination of bismuth and copper in the presence of muclear fast red[J]. Analytica Chimica Acta, 2006, 571(1): 99-104.
  • 5CARAPUCA H M, MONTERROSO S C C, ROCHA L S, et al. Simultaneous determination of copper and lead in seawater using optimised thin-mercury film electrodes in situ plated in thiocyanate media[J]. Talanta, 2004, 64(2): 566-569.
  • 6SAHIN C A, TOKGOZ L. A novel solidified floating organic drop microextraction method for preconcentration and determination of copper ions by flow injection flame atomic absorption spectrometry[J]. Analytica Chimica Acta, 2010, 667(1/2): 83-87.
  • 7AFZALI D, MOSTAFAVI A, TAHER M A, et al. Flame atomic absorption spectrometry determination of trace amounts of copper after separation and preconcentration onto TDMBAC-treated analcime pyrocatechol-immobilized[J]. Talanta, 2007, 71(2): 971-975.
  • 8TUNCEL S G, YENISOY-KARAKAS S, DOGANGUN A. Determination of metal concentrations in lichen samples by inductively coupled plasma atomic emission spectroscopy technique after applying different digestion procedures[J]. Talanta, 2004, 63(2): 273-277.
  • 9MITIC S S, MICIC R J, SIMONOVIC R M. Analytical application of food dye sunset yellow for the rapid kinetic determination of traces of copper (II) by spectrophotometry[J]. Food Chemistry, 2009, 117(3): 461-465.
  • 10NOOKABKAEW S, RANGKADILOK N, SATAYAVIVAD J. Determination of trace elements in herbal tea products and their infusions consumed in thailand[J]. Journal of Agricultural and Food Chemistry, 2006, 54(18): 6939-6944.