期刊文献+

具有闭环系统的法拉第电流传感器 被引量:2

Faraday Effect Current Sensor in a Closed-Loop Mode
下载PDF
导出
摘要 利用法拉第效应建立了一种偏振结构的电流传感器,它具有闭环反馈系统,从输出端反馈的电流信号驱动偏振调制螺线管产生补偿信号使传感器工作在正交状态,这样就有效地消除了费德尔常数变化给传感器带来的误差.该传感器线性测量范围是:1mA~6.5A。 A novel fiber-optic polarimetric configuration for a currert sensorutilizing the Faraday effeet is described. The spstem is operated in a closed-loopmode. Magneto optic feedback through a simple current driven solenoid maintainsthe sensor onto the quadrature condition. In this mode of operation sensor errorsdue to changes in the Verdet constant of the fiber are effectively eliminated. Ameasurement range with linear operation is from 1 mA to 6.5 A.
作者 王廷云
机构地区 哈尔滨工业大学
出处 《传感器技术》 CSCD 1997年第1期33-35,共3页 Journal of Transducer Technology
关键词 法拉第效应 电流传感器 闭环系统 Faraday effect Current sensor Closed-loop system
  • 相关文献

参考文献1

共引文献7

同被引文献39

  • 1易本顺,刘延冰,李尔宁.光学电流传感器的一种间接补偿方法[J].传感技术学报,1996,9(1):11-14. 被引量:4
  • 2易本顺,刘延冰,阮芳.光学电流传感器灵敏度的提高[J].传感器技术,1996,15(3):38-40. 被引量:1
  • 3王廷云 杨志国 等.光纤高压电流传感器[J].光子学报,1999,28(1):411-416.
  • 4Ning Y N, Wang Z P, Palmer A Wetal.. Recent progress in opticalcurrentsensingtechniques. Rev. Sci. Instr., 1995, 66(5):3097~3111.
  • 5Wang Z P, Zhang S Q, Zhang L B. Recent advances in optical currentsensing techniques. Sensors &Actuators A, 1995, 50(3):169~175.
  • 6Kang H S, Lee J H, Lee K S. A stabilization method of the Sagnac optical fiber current sensor with twist control. IEEE Photon.Technol. Lett., 1998, 10(10): 1464~1466.
  • 7Lin H, Lin W W, Chen M H. Modified in-line Sagnac interferometer with passive demodulation technique for environmental immunity of a fiber-optic current sensor. Appl. Opt., 1999, 38(13): 2760~2766.
  • 8Short S X, de Arruda J U, Tselikov A A et al.. Elimination of birefringence induced scale factor errors in the in-line Sagnac Interferometer current sensor. J. Lightwave Technol., 1998, 16(10): 1844~1850.
  • 9Short S X, Tselikov A A, de Arruda J U et al.. Imperfect quarter-waveplate compensation in Sagnac interferometer-type current sensors. J. Lightwave Technol., 1998, 16(7): 1212~1219.
  • 10Chan M F, Chen G S, Demokan M S et al.. Optimal sensing of current based on an extrinsic Sagnac interferometer configuration. Opt. Lasers in Engng., 1998, 30:17~24.

引证文献2

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部