摘要 证明曝气生物滤池废水深度处理时在适当的条件下能够进行同步硝化反硝化脱氮,影响同步硝化反硝化的因素有温度、溶解氧(DO)、pH值和CODCr/N比等.通过实验得出在温度20~28℃,DO为0.8~1.5mg/L,pH值7.2~8,CODCr/N为6.9~9.2下,同步硝化反硝化作用效果最明显,TN的去除率为最大,平均值分别为63.4%,66.9%,65.5%和67.2%. The simultaneous nitrification and denitrification (SND) can process in a good condition in water deep treating using Biological Aerated Filter (BAF). The factors affected SND are temperature, DO, pH and ratio of C/N and so on. The impression of SND is obvious on the condition that the temperature is 20-28℃, DO 0. 8-1.5 mg/L, pH 7. 2-8 and C/N 6. 9-9.2, on which the ratio of TN removal is the highest. The average ratio of TN removal is 63. 4%, 66. 9%, 65.3% and 67. 2% on each condition.
出处 《东华大学学报(自然科学版)》 CAS CSCD 北大核心 2007年第1期125-129,共5页 Journal of Donghua University(Natural Science)
关键词 曝气生物滤池 废水深度处理 同步硝化反硝化 影响因素 BAF water deep treating mechanism of SND influencing factor
  • 相关文献

参考文献10

  • 1高廷耀 夏四清 周增炎.城市污水生物处理脱氮除磷机理研究进展.中国给水排水,1996,12(5):32-32.
  • 2张鹏,周琪,屈计宁,顾国维.同时硝化与反硝化研究进展[J].重庆环境科学,2001,23(6):20-24. 被引量:16
  • 3ROBERSTON L A, KUENNEN J G. Aerobic Denitrification: a Controversy Revive [J]. Arch Microbiol, 1984,139:351 - 354.
  • 4LLOYD D, BODDY L, DAVIES K J P. Persistence of Bacterial Denitrification Capacity under Aerobic Conditions: the Rule Rather than the Exception [J]. FEMS Microbiol Eco1,1987,45:185 - 190.
  • 5冯叶成,王建龙,钱易.同时硝化反硝化的试验研究[J].上海环境科学,2002,21(9):527-529. 被引量:49
  • 6HYUNG S Y. Nitrogen Removel from Synthetic Wastewate by Simultaneous Nitification and Denltrilqcation (SND) via Nitrite in a Intermittently-Aerated Reactor [J]. Wat Res, 1999,33(1): 145- 154.
  • 7HELMER C, KUNST S. Simultaneous Nitrification/Denitri- Fication in an Aerobic Biofilm System [J]. Wat Sci Tech, 1998,37(4- 5): 183 - 187.
  • 8POCHANA K, KELLER J. Study of Factors Affecting Simultaneous Nitrification and Denitrification (SND) [J]. Wat Sci Tech, 1999, 39(6): 61-68.
  • 9MASUDA S, WATANABE Y, ISHIGURO M. Biofilm Proerties and Simultaneous Nitrification and Denitrifieation in Aerobic Rotating Biological Contactors[J]. Wat Sei Tech, 1991,23(6) : 1355 - 1363.
  • 10HO K. Biological Nutrient Removal in Activated Sludge Processes with Low F/M, Sludge Bulking Control [D]. Australia: University of Queensland, 1994.

二级参考文献10

  • 1顾夏声.废水生物处理数学模式(第二版)[M].北京:清华大学出版社,1997.54-65.
  • 2张自杰.排水工程(第三版)[M].北京:中国建筑工业出版社,1996..
  • 3Hong W,Wat Res,1999年,33卷,4期,961页
  • 4郑兴灿,污水除磷脱氮技术,1998年
  • 5Bang D Y,Sci Tech,1995年,32卷,8期,235页
  • 6Yang L,Wat Sci Tech,1992年,25卷,5/6期,997页
  • 7许保玖,当代给水与废水处理讲义,1983年
  • 8吕锡武,给水排水,26卷,4期,141页
  • 9袁林江,彭党聪,王志盈.短程硝化—反硝化生物脱氮[J].中国给水排水,2000,16(2):29-31. 被引量:233
  • 10吕锡武,李峰,稻森悠平,水落元之.氨氮废水处理过程中的好氧反硝化研究[J].给水排水,2000,26(4):17-20. 被引量:103