摘要
国电石嘴山发电厂#9汽轮机大修后,机组振动超标。经过多次对该机振动的测试分析,找到了原因。经过处理,成功解决了该机振动大的问题。
After overhauling of No.9 steam turbine in Shizuishan Power Plant, the units vibration test exceeds the standard, testing and analyzing the units vibration time after time, finds out the cause of vibration, solves the problem successfully.
出处
《宁夏电力》
2007年第2期52-54,共3页
Ningxia Electric Power
关键词
汽轮机
临界转速
振动
steam turbine
critical rotating speed
vibration