文章介绍了氨水碱化烘干法在燃气—蒸汽联合循环机组停用保养中的可行性分析,经过实际应用检验,证明这种方法是一种经济性和有效性都很好的停用保养方法。
The paper briefs the feasibility analysis of application of liquid ammonia alkalinization drying method in the shut-down period maintenance of gas-steam combined cycle anit.The actual practice demonstrates that this method is an economical and effective shut-down maintenance method.
出处
《电力设备》
2007年第5期27-29,共3页
Electrical Equipment
关键词
余热锅炉停炉腐蚀
氨水碱化
操作
保养效果
corrosion of boiler in shut-down period
liquid ammonia alkalinization
operating
maintenance effect