摘要
为了保证在大震作用下框架结构的稳定性,本文借鉴欧洲规范EC8“柱-梁承载力级差系数”的取值,提出了对部分抗震等级的框架结构的柱端抗弯能力增强系数应予以提高,以降低框架柱屈服的可能性。
To guarantee the stability of the frame in strong earthquake motion, and on the basis of analysis on the coefficients by the European Prestandard Euroeode 8, it is advised that the moment amplification coefficients at the bottom sections of columns for frame structures in some seismic intensity be increased to reduce the possibility of the frame column yielding.
出处
《福建建设科技》
2007年第3期32-33,共2页
Fujian Construction Science & Technology
关键词
结构抗震设计
承载力级差设计
抗震措施
强柱弱梁
structual seismic design
capacity design
seismic fortification measures
strong column -weak beam