摘要 针对当前矿井漏电检测系统中保护动作速度慢、漏电检测困难的情况,依据零序电流有功分量的原理,设计了一种采用TMS320LF2407DSP和SPCE061A单片机的矿井漏电检测系统。详细阐述了其工作原理、硬件组成及软件设计方案。该系统通过零序电压和零序电流采样和A/D转换后,利用TMS320LF2407快速运算能力进行数据处理,得到零序电压、电流有效值和零序有功功率;CPLD实现对零序有功功率与给定功率进行比较以决定漏电保护电路的是否启动,并实现语音报警和与上位机串行通讯的功能。该系统稳定、可靠,具有运算速度快、实时性强等特点。 Base on the principle of active component of zero-sequence current, a new mine current leakage measurement system based on TMS320LF2407DSP and MCU SPCE061A is designed to resolve the slow response in protection,the difficulty in current leakage detection, and the other problems with current mine current leakage measurement systems. Its working principle, hardware constitution, and design blue print of software are expatiated in details. By taking advantage of the high speed operation capability of TMS320LF2407 to perform data processing, this system can obtain zero-sequence vohage and zero-sequence current through the sample to zero-sequence voltage and zero-sequence current and A/D conversion. CPLD is used to compare zero-sequence active component power with the given power to determine whether drive current leakage measurement circuit, and to fulfill voice alert and the serial communication with computer. This system is more stable and reliable, and futures high operation speed and better real time response.
出处 《水利电力机械》 2007年第5期64-66,69,共4页 Water Conservancy & Electric Power Machinery
关键词 DSP 单片机 零序电压 零序电流 有功功率 DSP MCU zero-sequence voltage zero sequence current active component power
  • 相关文献

参考文献7

二级参考文献15

共引文献31

同被引文献7

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部