指出在计量工作中按照GB/T1884-2000方法测定成品油密度的实际操作中所存在的计量器具的不合格、样品采集方法的错误使用、温度计不当操作及对测量结果的错误处理等一系列问题,并针对所存在的问题进行理论分析,提出正确操作方法。
A series of issues in determining the density of refined oil by method GB/T 1884-2000 are pointed out, which included the unqualified measurement appliances, the misuse of taking sample method, the incorrect operation of thermometers, the improper disposal of the determining results and so on. Then, the correct operational methods are presented on the bases of the theoretical analysis of these issues.
出处