摘要
对国标“GB/T18204.26-2000酚试剂比色法”和XP-308型甲醛分析仪进行样品的对比实验分析及显著性差异的检验,得出了XP-308型甲醛分析仪与酚试剂比色法两种方法无显著性差异。并对XP-308型甲醛分析仪检测室内空气中甲醛含量的优势进行了分析。
On the basis of comparative tests and examinations of the notable difference for samples by using National Standard"GB/ T18204.26-2000.Phenol Reagent Method" and XP-308 monitor it is concluded that the two methods are not marked difference. So XP-308 monitor is recommended for determination of formaldehyde in indoor air with analysis of its superiority.
出处
《建筑科学》
北大核心
2007年第5期59-60,共2页
Building Science
关键词
甲醛分析仪
酚试剂比色法
对比研究
monitor of formaldehyde
phenol reagent method
comparative study