期刊文献+

同位素稀释质谱法测定人血清中痕量硒 被引量:4

Determination of selenium in serum samples by Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry(ID-ICP-MS)
下载PDF
导出
摘要 对巯基棉分离硒的方法进行了改进,建立了一种IMEP-17人血清样品中痕量硒的同位素稀释电感耦合等离子体质谱测量方法。采用微波消解-巯基棉分离对人血清样品进行前处理,通过对巯基棉分离血清中硒的条件优化,结果表明,柱条件为5 mol/L HCl、解脱Se条件为1 mL重蒸HNO3、巯基棉最佳用量为0.14 g时,能够有效分离出人血清样品中的Na、Mg、K、Ca等碱金属和碱土金属,同时硒的回收率最高,达到92%以上。将该前处理方法应用到同位素稀释电感耦合等离体质谱法中,平行取样6次,测量结果的平均值为(0.07747±0.00046)μg/g,在标准值(0.07896±0.0027)μg/g的不确定度范围内。 A method for the determination of selenium in serum samples ( IMEP- 17) by Isotope Dilution- Inductively has been developed. The serum selenium is first digested by International Measurement Evaluation Programme Coupled Plasma-Mass Spectrometry (ID-ICP-MS) microwave treatment and then chemically purified before analysis by using sulphydryl cotton. The optimum conditions were found to be as follows: (1) The sulphydryl cotton column is prewashed with 5 mol/L hydrochloric acid; (2) Se is desorbed by adding 1 mL of concentrated nitric acid and (3) the optimum amount of sulphydryl cotton is 0.14 g. This preconcentration step is required in order to remove matrix-interfering elements, such as Na, Mg, K and Ca. The recovery of selenium is above 92 %. The proposed ID-ICP-MS method has been used to determine Se in reference serum materials and the results of six independent measurements (average value is (0. 07747 ± 0. 00046) μg/g) showed good agreement with the certified value((0.07896 ± 0.0027)μg/R).
出处 《北京化工大学学报(自然科学版)》 EI CAS CSCD 北大核心 2007年第3期293-295,共3页 Journal of Beijing University of Chemical Technology(Natural Science Edition)
关键词 同位素稀释质谱法 多接收电感耦合等离子体质谱 微波消解 巯基棉 人血清 isotope dilution mass spectrometry multiple collector inductively couple mass spectrometry microwave digestion sulphydryl cotton selenium serum
  • 相关文献

参考文献5

  • 1周形海.微量元素与疾病[M].北京:人民军医出版社,1987:15.
  • 2HINOJOSA REYES L,MARCHANTE GAYON J M,GARCIA AlONSO J I,et al.Determination of selenium in biological materials by isotope dilution analysis with an octapole reaction system ICP-MS[J].J Anal At Spectrom,2003,18:11-16.
  • 3NARASAKI H,CAO Junyan.Determination of arsenic and selenium in river water by hydride generation inductively coupled plasma-mass spectrometry[J].Ana1ytical Sciences,1996,12:624.
  • 4蔡秋.氢化物原子荧光光谱法测定水产品中的痕量汞[J].光谱实验室,2003,20(1):98-101. 被引量:9
  • 5ROUXEI O,LUDDEN J,CARIGNAN J,et al.Natural variations of Se isotopic composition determinationed by hydride generation multiple collector inductively coupled plasma mass spectrometry[J].Geochimica et Cosmochimica Acta,2002,66(18):3191-3199.

二级参考文献4

共引文献10

同被引文献87

引证文献4

二级引证文献32