摘要 为获得同一时刻,不同频率下的生物电阻抗信息,本文采用混频激励模式,对生物电阻抗进行测量。为了提高系统的测量精度,本文在虚参考矢量方法与乘法解调技术相结合的测量方法基础上构建而成。系统设计中采用了模块化设计思路,并通过DSP实现对各个模块的控制功能。上位机软件采用VB语言编写,主要实现对下位机配置、串口通信、显示数据等功能。以阻容器件为对象,利用Agilent4294A阻抗分析仪对系统进行了标定,证明该系统具有较高精度和准确性;以人体为对象,也获得与阻抗分析仪测量结果趋势一致的生物阻抗信息。 In order to acquire the bioelectrical impedance information at different frequencies concurrently, a new measurement system was developed using a mixing frequency approach. The system design is based on the virtual reference vector method and multiplication demodulation technique. The implementation of the system hardware is a- chieved using a modular structure. A digital signal processor controls various modules in the system, and the system software realizes configuration of the digital signal processor, serial communication and data presentation, etc. A reference impedance analyzer (Agilent 4294A) is used to provide reference data in order to evaluate the developed system. Results obtained on a human body show that the system performs well in terms of functionality and accuracy.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2007年第6期961-965,共5页 Chinese Journal of Scientific Instrument
基金 Supported by Natural Science Foundation of China(60301008,50337020,60672076) Youthful Teacher Foundation of Tianjin University
关键词 混频测量 乘法解调 虚参考矢量 mixing frequency measurement multiplication demodulation virtual reference vector
  • 相关文献

参考文献1

二级参考文献6

  • 1Rosell J, et al. Bio-impedance active electrode for in vivo measurement[J]. Medical & Biological Engineering and Computing, 1994, 20(6): 300-303.
  • 2Wang Mi, Dickin F J, et al. Improved electrical impedance tomography and collection system and measurement protocols[J]. ECAPT, 1992, 3: 40-53.
  • 3Bertemes-Filho P, et al. Comparsion of current generators[J]. Physiol Meas, 2000, 21: 1-6.
  • 4Yang W Q, et al. New AC-based Capacitance Tomography System[J]. IEE Proc-Sci Meas Technol, 1999, 146(1): 335-343.
  • 5方红斌,胡书屏.AD7008在数字频率合成器中的应用[J].电子与仪表,1999(1):35-37. 被引量:2
  • 6王化祥,王艳儒.用于EIT成像系统的AD7008 DDS调制器[J].电子测量技术,1999,22(4):17-20. 被引量:12