靶控输注异丙酚意识消失时血浆和效应室靶浓度的EC(50)与脑电双频谱指数的关系 多中心大样本临床研究 被引量:46

Relationship between bispectral index and target plasma and effect-site EC50 for propofol by targetcontrolled infusion at loss of consciousness: a multicenter clinical study
原文传递
导出
摘要 目的 研究择期手术患者靶控输注(TCI)异丙酚意识消失时血浆、效应室靶浓度的50%患者意识消失时的药物浓度(EC50)与脑电双频谱指数(BIS)的关系。方法 5家医疗中心405例择期手术患者(国人),ASAⅠ或Ⅱ级。靶控输注异丙酚,以血浆靶浓度1.2μg/ml为起点,到达预期血浆靶浓度后每30秒递增0.3μg/ml,直至患者意识消失。采用概率单位回归分析计算患者意识消失时异丙酚血浆靶浓度、效应室靶浓度的EC05、EC50和EC95及其所对应的BIS。结果 择期手术患者TCI异丙酚意识消失时异丙酚血浆靶浓度EC05、EC50和EC95分别是2.9μg/ml、3.8μg/ml和4.8μg/ml,效应室靶浓度EC05、EC50和EC95分别是1.3μg/ml、2.2μg/ml和3.2μg/ml,50%患者意识消失的BIS是58,5%和95%患者意识消失的BIS分别是77和40。结论 择期手术患者TCI异丙酚意识消失时血浆靶浓度和效应室靶浓度EC50及95%置信区间分别是3.8μg/ml(3.8~3.9μg/ml)和2.2μg/ml(2.2~2.3μg/ml), 50%患者意识消失的BIS用95%置信区间是58(58~59)。 Objective To investigate the relationship between bispectral index (BIS) and target plasma andeffect-site EC50 for propofol given by target-controlled infusion (TCI) at loss of in Chinese patients scheduled for elective operation. Methods Four hundred and five ASA Ⅰ or Ⅱ Chinese patients (97 male, 308 female) aged 18-64 yr scheduled for elective operation in 5 medical centers were anesthetized with propofol by TCI using Diprifiusor TCI system incorporating Graseby 3500 infusion pump controlled by a computer programmed with the pharmacokinetic set of Marsh et al. The TCI of propofol was started at a target plasma concentration of 1.2 μg/ml, followed by increments of 0.3 μg/ml at 30 s intervals until the patient lost A quantal response model (probit analysis) was used to calculate the target plasma and effect-site EC05, EC50 and ED95 for propofol. HR, MAP, SpO2 and BIS were continuously monitored before and during anesthesia and recorded. Results The target effect-site EC05, EC50 and EC95 for prepofol at loss of were 1.3, 2.2 and 3.2 μg/ml respectively, while the target plasma EC05, EC50 and ED95 for propofol at loss of while 5 % The target were 2.9, 3.8 and 4.8 μg/ml. Fifty and 95 % of the patients lost percent of the patients lost consciousness at a BIS value of 58 ; at the BIS values of 77 and 40 respectively. Conclusion plasma and effect-site EC50 for propofol at loss of were 3.8 μg/ml (3.8-3.9 μg/ml) and 2.2 μg/ml (2.2-2.3 μg/ml) respectively in Chinese patients. The BIS value at loss of consciousness was 58 (58- 59).
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 2007年第4期324-327,共4页 Chinese Journal of Anesthesiology
关键词 二异丙酚 药物释放系统 意识丧失 脑电描记术 剂量效应关系 药物 Propofol Drug delivery systems Unconsciousness Electroencephalography Doseresponse relationship, drug
  • 相关文献

参考文献5

  • 1于布为,彭章龙,赵永泉.高龄病人异丙酚分步TCI时效应室浓度及BIS的变化[J].中华麻醉学杂志,2002,22(12):711-714. 被引量:44
  • 2Milne SE, Tory A, Irwin MG, et al. Relationship between bispectral index, auditory evoked potential index and effect-site EC50 for propofol at two clinical end-points. Br J Anaesth, 2003, 90:127-131.
  • 3Swinhoe CF, Peacock JE, Glen JB, et al. Evaluation of the predictive performance of a "Diprifusor" TCI system. Anaesthesia, 1998, 53 Supple 1:61-67.
  • 4Coetzee iF, Glen JB, Wium CA, et al. Pharmacokinetic model selection for target-controned infusion of propfol. Anesthesiology, 1995, 82: 1328- 1345.
  • 5Tackely RM, Lewis GTR, Roberts CP, et al. Computer eontroned infusion of propofol. Br J Anaesth, 1989,62:46-53.

二级参考文献9

  • 1Chernik DA, Gillings D, Laine H, et al. Validity and reliability of the observer's assessment of alertness/sedation scale: study with intravenous midazolam. J Clin Psychopharmacol, 1990, 10: 244-251.
  • 2Swinhoe CF, Peacock JE, Glen JB, et al. Evaluation of the pre-dictive performance of a "Diprifusor" TCI system. Anaesthesia,1998, 53(Suppl) : 61-67.
  • 3Coetzee JF, Glen JB, Wium CA, et al. Pharmacokinetic model selection for target controlled infusions of propofol. Anesthesiology,1995, 82: 1328-1345.
  • 4Struys MM, Smet TD, Depoorter B, et al. Comparison of plasma compartment versus two methods for effect compartment-controlled target-controlled infusion for propofol. Anesthesiology, 2000, 92:399-406.
  • 5Wakeling HH, Zimmerman JB, Howell S, et al. Targeting effect compartment or central compartment concentration of propofol:what predicts loss of consciousness? Anesthesiology, 1999, 90: 92-97.
  • 6Kearse LA, Rosow C, Zaslavsky A, et al. Bispectral analysis of electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis. Anesthesiology, 1998, 88:25-34.
  • 7Malinga M, Peitfaux F, Lepage JY, et al. Dose-response relati-onship between target-controlled concentration of propofol and bispectral index. Br J Anaesth, 1998, 80(Suppl): A132.
  • 8Ibrahim AE, Taraday JK, Kharasch ED. Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol.Anesthesiology, 2001, 95: 1151-1159.
  • 9李海红,米卫东,张宏.不同时点丙泊酚浓度及双频指数变化的测定[J].临床麻醉学杂志,2001,17(9):473-475. 被引量:4

共引文献43

同被引文献311

引证文献46

二级引证文献307

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部