摘要
全介质自承式(ADSS)光缆的设计施工是一项综合性的系统工程。给出了ADSS光缆挂点的空间电位的控制值,在最大弧垂下光缆必须保持与各种交越物的安全距离,ADSS光缆配盘原则及配盘长度经验公式,介绍了耐张线夹、垂悬线夹、防振装置的配置情况,总结了ADSS光缆施工要点。
The design and construction of ADSS optic cable is a comprehensive system project. The control value of the space potential of ADSS optic cable is given. The optic cable must keep safe distance to all kinds of crossover objects in the maximal arc dangle. The arrangement principles and the experience formula of ADSS optic cable length are brought out. The configuration of strain clips, dangle clips and vibration isolation equipments are introduced. The construction point of ADSS optic cables is summarized.
出处
《江苏电机工程》
2007年第3期54-56,共3页
Jiangsu Electrical Engineering
关键词
电力通信网
ADSS光缆
挂点
弧垂
金具配置
electric communication network
ADSS optic cable
hanging point
arc dangle
hardware equipment