摘要 采用后外包钢管混凝土柱,钢结构组合楼面置换,核心筒剪力墙粘钢加固等方法对中国民生银行总部大厦进行改扩建设计。建筑高度由原134.7m增至188.6m,建筑面积增加约3万m2。介绍了结构体系和抗侧力体系的确定、结构计算分析、结构加固方法、高强灌浆材料选择、钢结构置换施工顺序及节点构造等内容。 China Minsheng Bank Mansion is reconstructed and expanded by the methods of RC column post-covered steel tube, composite steel and concrete floor substitution and core wall externally bonded steel frames strengthen etc. The height of building is increased from 134.7m to 188.6m and the total area is enlarged 30 000m^2 . Contents of structural design for the mansion are introduced, including structural system establishment, structural analysis, seismic design, structure reinforcing methods, high strength material selection, substitute subsequence from concrete floors to composite steel-concrete floors and joint connection etc.
出处 《建筑结构》 CSCD 北大核心 2007年第5期125-129,共5页 Building Structure
关键词 超高层建筑 改扩建 置换 后包钢管混凝土柱 边缘构件 粘钢加固 super high-rise building reconstruction expansion substitution post-concrete-filled steel tubular reinforced column edge element steel bending reinforcement
  • 相关文献

参考文献13

  • 1(GB50017-2003).钢结构设计规范[S].[S].北京,2003..
  • 2(GB50011-2001).建筑抗震设计规范[S].[S].,..
  • 3混凝土结构加固设计规范审定稿(GB50367-2006)[S].
  • 4钢管混凝土结构设计与施工规程(CECS28:90)[S].
  • 5混凝土结构后锚固技术规程(JGJ145-2004)[S].
  • 6(CECS25:90).混凝土结构加固技术规范[S].[S].,..
  • 7现有建筑抗震鉴定与加固规程(DGJ08-81-2000)[S].上海市工程建设规范,2000.
  • 8纤维增强复合材料加固混凝土结构技术规程(DG/T108-012-2002)[S].上海市工程建设规范,2002.
  • 9中国民生银行大厦改造加固工程试验报告[R].同济大学结构工程与防灾研究所,2006.
  • 10中国民生银行大厦改造加固工程现场节点试验报告[R].同济大学结构工程与防灾研究所,2006.

共引文献92

同被引文献17

引证文献4

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部