摘要 根据三点弯曲缺口梁的荷载与裂缝张开位移曲线,用反分析法确定了钢纤维水泥砂浆的拉伸残余强度。试验制作了5种不同体积含量的钢纤维水泥砂浆试件。采用虚拟裂缝模型用有限元法数值模拟了三点弯曲缺口梁的荷载与裂缝张开位移,用反分析法确定了钢纤维水泥砂浆的弹性模量和拉伸残余强度。研究结果表明,数值模拟得到的钢纤维水泥砂浆弹性模量以及三点弯曲缺口梁荷载与裂缝张开位移曲线均与试验结果吻合较好,且在常用的钢纤维含量范围内,钢纤维水泥砂浆的残余强度与钢纤维含量基本上成正比。 The residual tensile strength of steel fiber reinforced mortar (SFRM) was determined by inverse analysis by using load versus crack mouth opening displacement (CMOD) curve from notched beam tests. Five series of SFRM with different volume fractions were tested. The load-CMOD curve was numerically obtained by using finite element method, then the elastic modulus and residual tensile strength of SFRM were determined by using inverse analysis. It was shown that the simulated elastic modulus and load-CMOD curve were both in good agreement with experimental results. Furthermore, it was found that the residual tensile strength of SFRM was approximately proportional to the volume fraction of steel fibers.
出处 《武汉理工大学学报》 EI CAS CSCD 北大核心 2007年第5期82-85,共4页 Journal of Wuhan University of Technology
基金 湖北省教育厅项目(2003B001) 湖北省自然科学基金(2003ABA083)
关键词 钢纤维水泥砂浆 虚拟裂缝模型 反分析 拉伸残余强度 steel fiber reinforced mortar fictitious crack model inverse analysis residual tensile strength
  • 相关文献

参考文献9

  • 1Trottier J F,Banthia N.Toughness Characterization of Steel-fiber Reinforced Concrete[J].Journal of Materials in Civil Engineering,1994,6(2):264-289.
  • 2Hillerborg A.Analysis of Crack Formation and Crack Growth in Concrete by Means of the Fracture Mechanics and Finite Elements[J].Cement and Concrete Research,1976,6(6):773-782.
  • 3RILEM TC 162-TDF.Test and Design Methods for Steel Fiber Reinforced Concrete:Design of Steel Fiber Reinforced Concrete Using the σ-w Method:Principles and Applications[J].Materials and Structures,2002,35:262-278.
  • 4Wang Y,Li V C,Backer S.Experimental Determination of Tensile Behavior of Fiber Reinforced Concrete[J].ACI Material Journal,1990,87(5):461-468.
  • 5Barragán B,Gettu R,Martín M A,et al.Uniaxial Tension Test for Steel Fibre Reinforced Concrete-A Parametric Study[J].Cement and Concrete Composites,2003,25:767-777.
  • 6Alberto M,Giovanni A P.New Design Approach for Steel Fiber-reinforced Concrete Slabs-on-ground Based on Fracture Mechanics[J].ACI Structural Journal,2004,101(3):298-303.
  • 7Sousa J L A O,Gettu R.Determining the Stress-crack Opening Curve of Concrete by Inverse Analysis[J].Journal of Engineering Mechanics,2006,132(2):141-148.
  • 8Bazant Z P,Planas J.Fracture and Size Effect in Concrete and Other Quasibrittle Materials[M].London:CRC Press,1998.
  • 9Roelfstra P E,Wittmann F H.Numerical Method to Link Strain Softening with Failure of Concrete[C]∥Fracture Toughness and Fracture Energy of Concrete.Amsterdam:Elsevier,1986.163-175.