期刊文献+

自锁板(钉)系统在下颌骨手术中的应用 被引量:2

原文传递
导出
摘要 不同类型的接骨板为下颌骨骨折和截骨提供了稳定的固定。传统接骨板(钉)系统的缺点是接骨板必须与骨面完全贴合才能防止在螺钉拧紧时,骨段凶适应接骨板形态而发生位置改变和咬合关系变化。自锁板(钉)系统在下颌骨骨折和骨缺损的治疗中所显现的优势远远超过其他板(钉)系统。通过将螺钉锁结徉板上而获得稳定性,自锁板(钉)系统的独特优势就足接骨板不必与骨而紧衔接触.
出处 《中华口腔医学杂志》 CAS CSCD 北大核心 2007年第6期381-384,共4页 Chinese Journal of Stomatology
  • 相关文献

参考文献22

  • 1Raveh J, Sutter F, Hellem S. Surgical procedures for reconstruction of the lower jaw using the titanium-coated hollowscrew reconstruction plate system: bridging of defects. Otolaryngol Clin North Am , 1987,20(3):535-355.
  • 2Sutter F, Raveh J. Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: biomechanical aspects, Int J Oral Maxillofac Surg ,1988,17(4) : 267 -274.
  • 3Soderholm AL, Lindgvist C, Skutnabb K, et al. Bridging of mandibular defects with two different reconstruction systems: an experimental study. J Oral Maxillofac Surg, 1991, 49 ( 10 ) : 1098 - 1105.
  • 4Herford AS, Ellis E 3rd. Use of a locking reconstruction bone plale/screw system for mandibular surgery. J Oral Maxillofac Surg, 1998,56( 11 ) : 1261-1265.
  • 5Ellis E 3rd, Graham J. Use of a 2.0-mm Locking plate/screw system for mandibular fracture surgery. J Oral Maxillofac Surg, 2002, 60(6) :642-645.
  • 6Haug RH, Street CC, Goltz M. Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates. J Oral Maxillofac Surg,2002, 60( 11 ) :1319-1326.
  • 7Jonsson H Jr, Cesarini K, Petren-Mallmln M, et al. Locking screw-plate fixation of cervical spine fractures with and without ancillary posterior plating. Arch Orthop Trauma Surg, 1991, 111 (1):1-12.
  • 8Vuillemin T, Raveh J, Sutter F. Mandibular reconstruction with the tilanium-hollow screwreconstruction plate syslem ( THORP ). Schweiz manatsschr Zaimmed, 1990,100 ( 6 ) : 701-708.
  • 9Sikes JW, Smith BR, Mukherjee DP, et al. Comparison of fixation strengths of locking head and conventional screws, in fracture and reconstruction models. J Oral Maxillofac Surg ,1998,56(4) :468-473.
  • 10Raveh J, Stich H, Sutter F, et al. Use of the titanium-coatcd hollow screw and reconstruction plate system in bridging lower jaw defects. J Oral Maxillofac Surg, 1984, 42(5) :281-294.

同被引文献28

  • 1高岚,查元坤,李谆,嵇宪生,张耀坤,周黎安.快速螺钉颌间固定的临床应用研究[J].口腔颌面外科杂志,2004,14(4):348-349. 被引量:14
  • 2吴亚东,张伟,于子莹,于立明,黄训,马宗民.下颌骨骨折坚固内固定有限元分析[J].现代口腔医学杂志,2006,20(2):175-178. 被引量:15
  • 3顾晓明.颌面部骨折内固定的新理念[J].中华口腔医学杂志,2007,42(2):65-66. 被引量:13
  • 4陈渝斌,柴鉴深,杨茂进,李万山.评价颌间结扎钉配合小型钛板联合治疗下颌骨骨折的临床应用[J].实用口腔医学杂志,2007,23(3):394-396. 被引量:9
  • 5Dos Santos DT,Costa E Silva AP, Wannier MW, et al. Validity of multislice computerized tomography for diagnosis of maxillofacial fracture using an in-dependent workstation[ J]. Oral Surg Oral Med Oral pathol Oral Radial Endod ,2004,98 (6) :715 - 720.
  • 6Terjesen T, Benum P. The stress-protecting effect of metal plates on the intact rabbit tibia[ J]. Acta Orthop Scand, 1983,54 (6) :810.
  • 7Dechow PC, Ellis E 3rd, Throckmorton GS. Structural properties of mandibular bone following application of a bone plate[J]. J Oral Maxillofac Surg, 1995,53 (9) : 1 - 44.
  • 8Alexander R, Theodos L. Fracture of the bone-grafted mandible secondary to stress shielding:report of a case and review of the literature[ J ]. J Oral Maxillofac Surg, 1993,51 (6) :695.
  • 9Kim YK, Yeo HH, Lim SC. Tissue response to titanium plates: atransmitted electron microscopic study [ J ]. J Oral Maxillofac Surg, 1997,55(4) :322 -326.
  • 10Bos RR, Boering G, Rozema, FR, et al. Resorbable poly( L-lactide) plates and screws for the fixation of zygomatic fractures[ J]. J Oral Maxillofac Surg, 1987,45 (9) :751 - 753.