讨论了高压变频器的失电再启动功能的动作机理、参数设置和应用中高压变频器失电再启动功能在电厂辅机应用中应解决的问题,通过给出实际应用案例和试验方案的形式,提出了高压变频器在完善失电再启动功能方面的改进方案和方向。
This article emphatically discusses the action mechanism, parameter' s setting and existing problems in application of high - voltage frequency converter' s function of restarting after power - loss, and proposes the improvement directions to consummate the high - voltage frequency converter' s function of restarting after power - loss.
出处
《山东电力技术》
2007年第3期43-48,共6页
Shandong Electric Power
关键词
变频器
失电再启动
低电压
frequency converter
restarting after power- loss
low voltage