期刊文献+

限制性内固定系统与半限制性内固定系统在脊柱融合中的应用比较 被引量:3

下载PDF
导出
摘要 近20年中,脊柱融合术得到迅猛发展,出现了各种不同的融合方法、器械和材料,以求提高融合率,获得较好疗效。在限制性内固定系统应用于脊柱融合术近60年后,其远期不良影响已被大家所认识。近年来,受长骨半限制性内固定系统研究的启发,有些学者将半限制性内固定系统应用于脊柱融合,并取得了一定的效果。现就限制性和半限制性内固定系统在脊柱融合中的应用综述如下。
出处 《上海医学》 CAS CSCD 北大核心 2007年第5期375-377,共3页 Shanghai Medical Journal
  • 相关文献

参考文献20

  • 1Christopher M.Bono CM,Lee CK.Critical analysis of trends in fusion for degenerative disc disease over the past 20 years:influence of technique on fusion rate and clinical outcome.Spine,2004,29:455-463.
  • 2Zdeblick TA.A prospective,randomized study of lumbar fusion.Preliminary results.Spine,1993,18:983-991.
  • 3Javedan SP,Dickman CA.Cause of adjacent-segment disease after spinal fusion.Lancet,1999,354:530-531.
  • 4Chen WJ,Lai PL,Niu CC,et al.Surgical treatment of adjacent instability after lumbar spine fusion.Spine,2001,26:E519-E24.
  • 5Hilibrand AS,Carlson GD,Palumbo MA,et al.Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis.J Bone Joint Surg Am,1999,81:519-528.
  • 6Maiman DJ,Kumaresan S,Yoganandan N,et al.Biomechanical effect of anterior cervical spine fusion on adjacent segments.Biomed Mater Eng,1999,9:27-38.
  • 7Axelsson P,Johnsson R,Stromqvist B.The spondylolytic vertebra and its adjacent segment.Mobility measured before and after posterolateral fusion.Spine,1997,22:414-417.
  • 8Etebar S,Cahill DW.Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability.J Neurosurg,1999,90(suppl 2):S163-S169.
  • 9Nagata H,Schendel MJ,Transfeldt EE,et al.The effects of immobilization of ong segments of the spine on the adjacent and distal facet force and lumbosacral motion.Spine,1993,18:2471-2479.
  • 10Chen CS,Cheng CK,Liu CL,et al.Stress analysis of the disc adjacent to interbody fusion in lumbar spine.Med Eng Phys,2001,23:483-491.

二级参考文献11

  • 1谭军,王鸣鹏,万卫平,张国桢,贾连顺,赵定麟,屠开元.正常人腰椎椎体解剖结构的 QCT 研究及其生物力学意义[J].中国临床解剖学杂志,1997,15(1):59-63. 被引量:28
  • 2McAfee PC, Farey ID, Sutterlin CE, et al. 1989 Volvo Award in basic science. Device-related osteoporosis with spinal instrumentation.Spine, 1989, 14: 919-926.
  • 3Smith KR, Hunt TR, Asher MA, et al. The eflect of a stiff spinal implant on the bone-mineral content of the lumbar spine in dogs. JBone Joint Surg (Am), 1991, 73:115-123.
  • 4Schimandle Jh, Boden SD. Spine update: the use of animal models to study spinal fusion. Spine, 1994, 19: 1998-2006.
  • 5Johnston CE 2nd, Welch RD, Baker K J, et al. Effect of spinal construct stiffness on short segment fusion mass incorporation. Spine,1995, 20: 2400-2407.
  • 6Ebbesen EN, Thomsen JS, Beck-Nielsen H, et al. Lumbar vertebral body compressive strength evaluated by dual-energy X-ray absorptiometry, quantitative computed tomography, and ashing. Bone, 1999,25: 713-724.
  • 7Farey ID, MacAfee PC, Gurr KR, et al. Quantitative histologic study of the influence of spinal instrumentation on lumbar fusions: a canine model. J Orthop Res, 1989, 7: 709-722.
  • 8McAfee PC, Farey ID, Sutterlin CE, et al. The effect of spinal implant rigidity on vertebral bone density: a canine model. Spine,1991, 16(6 Suppl): 190-197.
  • 9辛兵,侯筱魁,李永刚.脊柱内固定器的应力遮挡[J].中国矫形外科杂志,2000,7(2):154-155. 被引量:9
  • 10徐华梓,王向阳,池永龙,朱青安.增加载荷分享的动力椎弓根螺钉固定器的稳定性及其意义[J].中华外科杂志,2002,40(10):737-739. 被引量:10

共引文献1

同被引文献62

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部