摘要 推导了变压器油中溶解气体的分离数学模型,建立了一种用光纤M-Z干涉仪对低浓度氢气进行检测的实验系统.通过对气室引入声波调制手段,消除了环境因素对干涉仪的干扰。 A mathematical model for separating the hydrogen dissolved in transformer oil is developed. An experimental setup is built to measure extremely low hydrogen concentration based on a fiber optic M Z interferometer. By introducing sound wave modulation to the gas cell, all kinds of environmental interference to the interferometer are significantly reduced and the sensitivity of hydrogen concentration measurement is greatly improved.
出处 《华中理工大学学报》 CSCD 北大核心 1997年第2期49-51,共3页 Journal of Huazhong University of Science and Technology
基金 国家自然科学基金
关键词 油气分离 氢气浓度 检测 绝缘油 变压器 故障 fiber optic Mach Zeuhnder interferometer oil gas separation palladilium membrane hydrogen concentration measurement sound wave modulation
  • 相关文献

参考文献4

  • 1Zhang Wei,Proc SPIE.1527,1991年
  • 2何祚镛,声学理论基础,1991年
  • 3王龙甫,弹性理论,1984年
  • 4许元泽,聚合物的性质(译),1981年

同被引文献34

引证文献4