摘要
利用电化学腐蚀的方法在p型单晶硅(100)衬底上制备了多孔硅薄膜。利用微拉曼光谱法分别测量了处于湿化—干燥—再湿化3个阶段的多孔硅薄膜的拉曼频移,对多孔硅内应变引起的频移改变量和纳米硅晶粒因声子限制效应引起的频移改变量进行分离,找到多孔硅薄膜残余应力与拉曼频移之间的关系式。利用这一关系式,对不同孔隙率的多孔硅薄膜的残余应力进行了计算,获得了和声子模型拟合方法相一致的结果。研究中发现,多孔硅表面残余应力随孔隙率的增加而线性增大,其原因为随着孔隙率的增加,多孔硅晶格常数增大,且干燥过程中残液的蒸发产生的毛细应力使多孔硅薄膜与基体硅间晶格错配程度增大造成的。
Porous silicon films are obtained on highly level doped p-type (100)silicon wafers using electrochemical etching technology. Micro-Raman spectroscopy is used to characterize porous silicon in the three different stages: wetting-drying and rewetting, according to the Raman shifts as a result of different factors, the shift of phonon confinement effect resulted from nanocrystalline are separated from the shift that due to strain in porous silicon,a proper expression is found to calculate the stress according to Raman shift. And the stress is calculated on porous silicon surface with different porosity using this express. The results indicate that a larger tensile residual exists on the surface and increases linearly with the porosity, which due to the lattice mismatch between porous silicon and Si substrate and the degree of lattice mismatch higher with the porosity increasing and evaporation.
出处
《传感器与微系统》
CSCD
北大核心
2007年第6期15-17,19,共4页
Transducer and Microsystem Technologies
基金
国家自然科学基金资助项目(6007102760371030)
关键词
多孔硅
残余应力
微拉曼光谱
porous silicon
residual stress
micro-Raman spectroscopy