期刊文献+

真空开关在线监测系统的数据传输

Data transfer of on-line monitoring system for vacuum switches
下载PDF
导出
摘要 为了解决基于DSP的真空开关真空度在线监测系统的数据传输问题,把变电站中每一个开关柜内的在线监测装置设计成单一CAN总线节点形式,在减少数据传输量的基础上采用局域网和CAN总线作为通讯途径,同时,给出了主要部分的具体实现方案。该方法解决了传输的可靠性问题,较好地解决了与上位工控机或个人PC的接口问题,实现了网络远程监控。 In order to solve the data transfer problem of the on-line monitoring system based on DSP for vacuum degree of vacu um switches, the on-llne monitoring system was designed in every switch cabinet into a single node on CAN-Bus, in electric substation. After the data size reduced, the local area network (LAN) and CAN-Bus were adopted to transfer the data, the primary parts' implementation was also given. So the reliability problem in transmission solved, and easy to interface with epistemic industry computer or personal computer for system, At the same time, it can realize remote supervisory and controlling.
作者 袁松贵
出处 《机电工程》 CAS 2007年第6期33-36,共4页 Journal of Mechanical & Electrical Engineering
关键词 CAN总线 HPI接口 远程监控 ISA时序 CAN bus HPI interface remote supervisory and controlling ISA time sequence