期刊文献+

湛江奥里油发电厂电除尘器前烟道注氨系统

Ammonia Injection System on Flue Gas Duct before Electrostatic Precipitator Inlet in Zhanjiang Orimulsion Power Plant
下载PDF
导出
摘要 燃用奥里油发电对改善能源结构具有积极意义,但奥里油高硫分、高钒的特性,导致燃烧产物中三氧化硫含量较高,容易产生酸结露,腐蚀烟气系统中的静电除尘器,影响除尘效果并损坏设备。广东湛江奥里油发电厂采取了静电除尘器前烟道注氨的技术措施。为此,针对氨的特性,阐释了氨的储存、蒸发及注入系统流程,并重点介绍了该系统设计特色及主要设备的选择。 Orimulsion-fired power generation conduces to the improvement on energy structure. The high content of sulfur and vanadium in Orimulsion, however, leads to high content of sulfur trioxide in the combustion product and easily generates acidic dew, thus corroding the electrostatic precipitator (EP) in the flue gas system, impacting dust removal efficiency and damaging equipment. The ammonia injection technique on the flue gas duct before the EP inlet has been adopted in Zhanjiang Orimulsion Power Plant. The flows of ammonia storage, evaporation and injection system are illustrated. The design features of the system and the selection of main devices are explained emphatically.
作者 胡琨 马雪松
出处 《广东电力》 2007年第5期20-24,共5页 Guangdong Electric Power
关键词 奥里油 高硫分 硫氧化物 注氨系统 电除尘器 设计特色 Orimulsion high content of sulfur oxysulfide ammonia injection system electrostatic precipitator (EP) design feature
  • 相关文献

参考文献3

二级参考文献16

  • 1陆海珠,韩兵.电厂脱硫工程控制系统的分析与论证[J].电力环境保护,2004,20(4):11-14. 被引量:6
  • 2[2]胜利发电厂一号炉试烧乳化油总结报告[R]. 胜利发电厂,1997.
  • 3[3]杨妙兴.上海石油化工股份有限公司热电厂2号炉奥里油试烧试验报告[R]. 华东电力试验研究所,1998.
  • 4[4]日本奥里油发电技术考察报告[R]. 广东省电力设计研究院,2003.
  • 5KIM H S, SHIN M S, JANG D S. et al. Numerical study for the combustion characteristics of Orimulsion fuel in a smallscale combustor[J]. Applied Thermal Engineering, 211115, 25: 2998 - 3012.
  • 6JANANI K D. Program results for a comprehensive assessment of chemical emissions from New Brunswick Power's Dalhousie Station[R]. [S. L.]: Carnot, Inc. , 1997.
  • 7KANEKO S, IWANAGA A, HISHIDA M. Experience of Orimulsion fired power plant in Japan [C].Presented at Power-Gen International'96. Orlando: [s. n.], 1996.
  • 8MILLER C A, DREHER K, WENTSELL R, et al. Environmental impacts of the use of Orimulsion, report to congress on phase 1 of the Orimulsion technology assessment program [R] . Washington:U.S. Environmental Protection Agency, Office of Research and Development, 2001.
  • 9MEISINGSET L, MOLLER W, PEDERSEN P H. Experience from conversion of a 640 MW coal-and oil-fired unit into Orimulsion [C]//Proceedings of the 22nd International Technical Conference on Coal Utilization and Fuel Systems, Clearwater, FL: [s. n.], 1997.