摘要
大容积钢质无缝压力容器安全泄放装置的设置和安全泄放量的计算,按照国内标准应该采用GB 150—1998、JB 4732—1995和《压力容器安全技术监察规程》规定的方法和公式进行计算,但对于容器处于火灾环境时,安全泄放量的计算没有给出明确的方法,本文针对此问题进行了论述和探讨。
For large, seamless and steel pressure vessel, the set of safe relief valve and safe relief volume shall be in accordance with the methods and equations stipulated in GB 150-1998, JB 4732-95 and "Supervision Regulations on Safety Technology of Pressure Vessel". But, for the vessels locating fire environment, there is no any method for calculating the safe relief volume. In this article, this topic was discussed.
出处
《化工设备与管道》
CAS
2007年第3期16-18,共3页
Process Equipment & Piping
关键词
大容积钢质无缝压力容器
火灾环境
安全泄放量
计算方法
large, seamless and steel pressure vessel, fire environment, safe relief volume, calculation method