期刊文献+

基于场效应管开关阵列的GEM探测器读出方式

Pixel readout for GEM detectors based on switched field effect transistor array
原文传递
导出
摘要 为实现探测器信号成像要求,研究一种气体电子倍增膜(gas electron multiplier,GEM)探测器的读出方法。采用印刷电路技术,将读出电极盘与场效应管的分立元件组合构成阵列,通过场效应管开关阵列,读出GEM探测器信号,并实现成像。实测表明:该方法的动态范围(最大信号与噪声高宽的比值)可达7.3×104,积分非线性小于0.324%,灵敏度为2.55 V/nC,可实现30帧/s的实时成像。该方法具有制作工艺简单、参数可调、成本低等优点,为随后采用厚膜技术及薄膜场效应管技术读出GEM探测器提供了重要的设计依据。 A pixel readout for image formation was developed using gas electron multiplier (GEM) detectors. A switched array of pads and field effect transistors was constructed from single elements on a printed circuit board. Tests show that the dynamic range (ratio of maximum signal to full width at half maximum, FWHM, of noise) reaches 7.3 × 10^4, the integral nonlinearity is less than 0. 324%, the sensitivity is 2.55 V/nC, and the system can work in real time at 30 frames/s. This readout is simple, flexible, and low cost, and can be implemented using thick-film technology and thin film transistor technology.
出处 《清华大学学报(自然科学版)》 EI CAS CSCD 北大核心 2007年第6期855-858,共4页 Journal of Tsinghua University(Science and Technology)
基金 国家自然科学基金资助项目(10575063)
关键词 信号成像 读出方式 气体电子倍增膜 探测器 场效应管 开关阵列 image formation pixel readout gas electron multiplier (GEM) detectors field effect transistor (FET) switch array
  • 相关文献

参考文献8

  • 1Sauli F.GEM:A new concept for electron amplification in gas detectors[J].Nuclear Instruments and Methods in Physics Research A,1997,386:531-534.
  • 2LI Jin,LAI Yong-Fang,CHENG Jian-Ping,LI Yuan-Jing,LI Yu-Lan,YUE Qi.Current progress of study on gas electron multiplier[J].Nuclear Science and Techniques,2005,16(4):225-230. 被引量:1
  • 3Bressan A,De Oliveira R,Gandi A,et al.Two-dimensional readout of GEM detectors[J].Nuclear Instruments and Methods in Physics Research A,1999,425:254-261.
  • 4Tsyganov E,Buzulutskov A,Antich P.Triple GEM structure for medical imaging[C]∥IEEE Nucl Sci Syrup Med Imaging Conf Norfolk,VA,United States:IEEE Press,2002,2:1163-1166.
  • 5Colas P,Colijn A P,Fornaini A,et al.The readout of a GEM or Micromegas-equipped TPC by means of the Medipix2 CMOS sensor as direct anode[J].Nuclear Instruments and Methods in Physics Research A,2004,535:506-510.
  • 6Black J K,Deines-Jones P,Ready S E,et al.x-ray polarimetry with an active-matrix pixel proportional counter[J].Nuclear Instruments and Methods in Physics Research A,2003,513:639-643.
  • 7ZHAO Wei,Rowlands J A.Digital radiology using self-scanned readout of amorphous selenium[J].SPIE Physics of Medical Imaging,1993,1896:114-120.
  • 8XU Weize,Friedman E G.Clock feedthrough in CMOS analog transmission gate switches[J].Analog Integrated Circuits and Signal Processing,2005,44:271-281.

二级参考文献23

  • 1Oed A. Nucl Instr Meth, 2001, A471:109.
  • 2Sauli F. Nucl Instr Meth, 1997, A386:531.
  • 3Altunbas M C, Dehmelt K, Kappler S, et al. Nucl Instr Meth, 2003, A515:249.
  • 4Sauli F, Meinschad T, Musa L, et al. IEEE Nuclear Science Symposium, Norfolk, 2002.
  • 5MAXWELL Commercial Finite Element Computation Package. Ansoft Co. Pittsburgh, PA, USA.
  • 6Bachmann S, Bressan A, Capeans M, et al. Nucl Instr Meth, 2002, A479:294.
  • 7Inuzuka M, Hamagaki H, Ozawa K, et al. Nucl Instr Meth,2004, A525:529.
  • 8Pitts W K, Martin M D, Belolipetskiy S, et al. Nucl Instr.Meth, 1999, A438:277.
  • 9Barbeau P S, Collar G I, Geissinger J D, et al. Nucl Instr Meth, 2003, A515:439.
  • 10Fetal S, van Eijk C W E, Fraga E et al. Nucl Instr Meth,2003, A513:42.