摘要
本文通过对标准方法的再研究,结合监测仪器的特有性能,提出用两点定位法测定水质样品中的氟,通过对实验样品的精密度、准确度分析,本方法的标准偏差在0.3~1.8%之间,加标回收率在93~101%之间,符合环境监测的要求。
Objective:To establish and prove the method to determine the fluorine in water sample by using the two-point locating. Method: Through the proper study to the standard method and the performancc of monitoring equipment, the article establishes the method to determine the Fluorine in water sample by using the two-point locating. Result: Through the analysis to the accuracy and precision, The RSD of the method was 0.3-1.8%, and the recoveries were 93-101%. Conclusion: The accuracy and better repeatability of determination the Fluorine in water sample can be established though the two-point locating.
出处
《福建分析测试》
CAS
2007年第2期59-61,共3页
Fujian Analysis & Testing
关键词
两点定位
测定
样品
氟
two-point locating
determination
sample
Fluorine