摘要
提出了准低温仓的控温控湿要求,仓库改建的控温条件和控湿条件以及干燥、通风后期控温控湿技术措施。使高水分粮食通过采用干燥、通风技术将水分降低后,其储粮温度和水分都能控制在准低温仓要求的低限水平,以延缓粮食陈化,保持粮食品质。
The paper offers temperature and humidity control demand for quasi low temperature silo,temperature and humidity control conditions for rebuilding silo,and temperature and humidity control measures for silo in the late of drying and ventilating.The techniques of above could maintain temperature and moisture of grain in quasi low temperature silo at the low limit of demand after reducing the moisture content of high moisture grain with drying and ventilating equipments to prolong grain deterioration and keep grain quality.
出处
《郑州粮食学院学报》
1997年第1期26-33,共8页
Journal of Zhengzhou Institute of Technology
关键词
控温控湿技术
干燥
通风
粮食
储藏
仓库
temperature and humidity control technique
drying
ventilation
temperature and moisture control demand