摘要
用获FDA准许的美国CambridgeBiotech公司HIV-1蛋白印迹试剂盒(WB)对HIV-1/2抗体诊断试剂盒(ELISA)初筛阳性的62份血清标本做确证试验。一次性确证HIV抗体阳性者8名;阴性者12名;不确定者42名。对8名HIV抗体不确定者做追访采样监测,其中1人12天后WB血清HIV抗体由不确定性转为阳性,另7人在6~15个月经2~3次采样检测,WB区带反应无变化或略有变化。本研究证实WB不确定者,若有HIVenv(gp160、gp120、gp41)区带反应,HIV血清抗体可能转阳;若仅HIVpol(p31、p51、p66)和/或gag(P17、P24、P55)区带反应,很大可能是非特异性反应。虽ELISA阳性,而WB不确定者血清主要呈p24抗体反应(42.9%,18/42)与p24、p17抗体反应(28.6%,12/42)。
Total 62 HIV-1/2 ELISA screening positive samples were confirmed with US FDA licensed Cambridge Brotech HIV-1 Western Blot Kit,8 positive,12 negative and 42 indeterminate test resultes were confirmed one time.Follow-up testing 8 HIV WB-indeterminate specimens,one individual of them turned into WB-positive after 12 days,the other 7 collected specimens were tested 2-3 times by WB within 6~15 months,their WB reactivity bands were no change or a bit.Our experience indicates that WB-inditerminate serum HIV-antibody would change into WB-positive if there is HIV Eev (gp160 or gp120 or gp41)band on a strip.When there are just only HIV Pol(p31,p51,p66)and /or gag (p17,p24,p55)reactivity bands it will be properly nonspecific reaction.The most common band patterns of WB-indeterminate specimens are p24 (42.9%,18/42)and p24.p17(28.6%,12/42).
出处
《中国性病艾滋病防治》
1997年第2期79-82,共4页
Chinese Journal of Std & Aids Prevention and Control