期刊文献+

有源声学结构中误差传感器的最优布放 被引量:1

Optimum Arrangements of Error Sensors for Active Acoustic Structure
下载PDF
导出
摘要 误差传感器的最优布放是有源声学结构研究的关键问题之一,它对控制效果的好坏和控制系统的复杂程度有决定性的影响。研究了基于近场测量面声压传感的结构声辐射估计问题,给出了两种基于测量面声压的有源控制目标,在此基础上研究了误差传感器的最优布放规律。结果表明:误差传感器应布放在有源控制后测量面声压最小的区域内,一般分布在次级结构的周围,误差传感器的个数与次级结构的个数相等时,即可取得良好的有源控制效果。 Error sensor arrangements for active acoustic structure(AAS) is theoretically investigated in this paper. Error sensing strategies for active acoustic structure based on nearfield pressures are examined. Two kinds of cost functions using nearfield pressures are given. According to theoretic analysis and computer simulations, the optimum arrangements for error sensors in active acoustic structure are obtained.
出处 《电声技术》 2007年第6期56-63,共8页 Audio Engineering
关键词 有源声学结构 有源噪声控制 最优布放 active acoustic structure active noise control optimum arrangement
  • 相关文献

参考文献9

  • 1FULLER C R, ELLIOTT S J, NELSON P A. Active control of vibration[M]. San Diego:Academic Press, 1996.
  • 2陈克安.自适应声学结构声压误差传感策略[J].振动工程学报,2004,17(3):301-305. 被引量:14
  • 3ELLIOTT S J, STHOTHERS I M, NELSON P A. A multiple error LMS algorithm and its application to the active control of Sound[J]. IEEE Trans. on Acoustics, Speech, and Signal Processing, 1987,35(10) : 1 423-1 434.
  • 4SOMMERFELDT S D. Multi-channel adaptive control of structural vibration[J]. Noise Control Engineering Journal, 1991 (37) :77-89.
  • 5ELLIOTT S J, BOUCHER C C, NELSON P A. The behavior of a multiple channel active control system [J]. IEEE Trans. on Signal Processing,1992,40(5):1041-1052.
  • 6ELGRICHI Y, ZEHEB E. Stability of muhichannel sound control system[C]// Proceedings of IEEE.Visual Image Signal Processing. [S.l.] :IEEE Press, 1997,144 ( 1 ) : 1-7.
  • 7陈克安,尹雪飞.基于近场声压传感的结构声辐射有源控制[J].声学学报,2005,30(1):63-68. 被引量:25
  • 8BAI M R, TSAO M. Estimation of sound power of baffled planar sources using radiation matrices[J]. Journal of the Acoustic Society of America., 2002,112(3 ) : 876-883.
  • 9尹雪飞,陈克安.有源声学结构:概念、实现及应用[J].振动工程学报,2003,16(3):261-268. 被引量:17

二级参考文献64

  • 1CHENKe'an YINXuefei.Active control of radiated sound using nearfield pressure sensing[J].Chinese Journal of Acoustics,2004,23(3):193-202. 被引量:10
  • 2陈克安,马远良.自适应宽带有源消声[J].声学学报,1994,19(2):101-109. 被引量:11
  • 3Johnson M E, Elliott S J. Volume velocity sensors for active control. Proceedings of the Institute of Acoustics, 1993;15:411-420.
  • 4Friswell M I. On the design of modal actuators and sensors. Journal of Sound and Vibration, 2001; 241(3):361-372.
  • 5Vipperman J S, Clark R L. Implementation of an adaptive piezoelectric sensoriactuator. AIAA Journal,1996 ; 34 : 2102-2109.
  • 6Liang C, Rogers C A, Fuller C R. Acoustic transmission/radiation analysis of shape memory alloy reinforced laminated plates. Journal of Sound and Vibration, 1991;145:23-41.
  • 7Stanway R, Sproston J L, EI-Wahed A K. Applications of electro-rheological fluids in vibration control: a survey. Smart Materials and Structures, 1996 ;5:464-482.
  • 8Leng J, Asundi A. Active vibration control system of smart structures based on FOS and ER actuator. Smart Materials and Structures, 1999 ; 8 : 252-256.
  • 9Tanaka N, Snyder S D, Hansen C H. Distributed parameter modal filtering using smart sensors. ASME Journal of Vibration and Acoustics, 1996;118:630-640.
  • 10Turner R D, Valis T, Hogg W D, et al. Fiber-optic strain sensors for smart structures. Journal of Intelligent Material Systems and Structures, 1990;1:26-49.