期刊文献+

不同粘结剂对瓷-牙本质粘结剪切强度的研究 被引量:3

Pilot study on shear strength of porcelain-dentin bonding using different cements
原文传递
导出
摘要 目的:观察比较不同树脂粘结剂对IPS Empress 2全瓷基底粘结剪切强度的效果。方法:选择无龋坏的人磨牙24个,随机分为4组,每组6个。第1组用RelyX Veneer进行粘结。第2组用RelyX unicem进行粘结。第3组用RelyX ARC进行粘结。第4组用Variolink 2进行粘结。所有样本在37°C蒸馏水中储存24h后,进行测试,记录剪切强度值,用SPSS11.0对结果进行单因素方差分析,并在光学显微镜下观察粘结破坏情况。结果:RelyX Veneer、RelyX ARC、Variolink 2的剪切强度显著高于RelyX unicem的剪切强度(P<0.05),破坏界面多发生在牙本质与粘结剂之间。结论:RelyX Veneer、RelyX ARC、Variolink 2都可以用于IPS Empress 2全瓷系统的粘结。 Objective: to observe and compare the shear bond strength of different composite resincement systems to IPS Empress 2 all ceramic substrate. Method: 24 healthy non-carious human molars were selected in the study.The samples were divided into four groups, 6 in each group. (1)RelyX Veneer was used on bonding, (2)RelyX unicem was used on bonding, (3) RelyX ARCwas used on bonding, (4) Variolink 2 was used on bonding. All specimens were stored inwater at 37 ℃ for 24 hours. All specimens were stressed in shear until failure. Statisticalanalysiswasperformed by ANOVA with SPSS11.0.Debonged surface was examined with lightmicroscope.Result: Shear bond strengths of RelyX Veneer.RelyX ARC. Variolink 2 were significantly higher than that of RelyX unicem (p〈0.05).Conclusion: RelyX Veneer. RelyX ARC,Variolink 2 can be using to bonding IPS Empress 2 all ceramic. Supported by Shanghai Leadind Academic Discipline Project (0202) and National Natural Science Foundation of China (30672348).
出处 《临床口腔医学杂志》 2007年第6期331-333,共3页 Journal of Clinical Stomatology
基金 国家自然科学基金资助项目(30672348) 上海市重点学科(特色学科)建设项目(T0202)~~
关键词 树脂粘结剂 IPS EMPRESS 2 剪切强度 adhesive resin cement IPS Empress 2 shear bond strength
  • 相关文献

参考文献11

  • 1Thompson JY,Rapp MM,Parker AJ.Microscopic and energy dipersive x-ray analysis of surface adaptation of dentalcements to dental ceramic surfaces[J].J Prosthet Dent.1998,79 (4):378-383.
  • 2Groten M,Probster L.The influence of different cementation modes on the fracture resistance of feldspathic ceramic crowns.Int[J].J Prosthodont.1997,10 (2):169-177.
  • 3Della Bona A,Anusavice KJ,Mecholsky JJ Jr.Failure analysis of resin composite bonded to ceramic[J].Dent Mater,2003,19 (8):693-699.
  • 4Borges GA,Sophr AM,deGoes MF.Effect of etching and airborne particle abrasion on the microstructure of different dental ceramics[J].J Prosthet Dent,2003,89 (5):479-488.
  • 5Nagai T,Kawamoto Y,Kakehashi Y.Adhesive bonding of a lithium disilicate ceramic material with resin-based luting agents[J].J Oral Rehabil,2005,32 (8):598-605.
  • 6Della Bona A,Shen C,Anusavice KJ.Work of adhesion of resin on treated lithia disilicate-based ceramic[J].Dent Mater,2004,20 (4):338-344.
  • 7Kumbuloglu O,Lassila LV,User A.Shear bond strength of composite resin cements to lithium disilicate ceramics[J].J Oral Rehabil,2005,32 (2):128-133.
  • 8Akgungor G,Akkayan B,Gaucher H.Influence of ceramic thickness and polymerization mode of a resin luting agent on early bond strength and durability with a lithium disilicate-based ceramic system[J].J Prosthet Dent,2005,94 (3):234-241.
  • 9De Munck J,Vargas M,Van Landuyt K.Bonding of an auto-adhesive luting material to enamel and dentin[J].Dent Mater,2004,20(10):963-971.
  • 10Gerth HU,Dammaschke T,Zuchner H.Chemical analysis and bonding reaction of RelyXX Unicem and Bifix composites-A comparative study[J].Dent Mater,2006,22 (10):934-941.