期刊文献+

TCA2003全站仪自动识别系统ATR的实测三维精度分析 被引量:23

A study of the precision of TCA2003 total station automatic target recognition system in actual three-dimensional survey
下载PDF
导出
摘要 简述智能型全站仪TCA2003的自动目标识别(ATR)功能及其二次开发的机载测量软件的特点,以琅琊山抽水蓄能电站大坝变形监测网应用ATR功能三维测量实例,基于对其测量平差成果的评定精度,分析ATR三维测量的精度,比较ATR测量与常规的人工测量的功效,并给出有益的结论,为同类工程的应用以及拓展ATR全站仪应用领域提供技术依据。 The function of the automatic target recognition (ATR) system and the features of airborne survey software by quadratic developing of total station TCA2003 are introduced. By application of ATR in deformation monitoring network of Langya hill pumped storage hydropower station, and based on its evaluating precision three-dimensional measurement precision is analyzed and ATR measurement and conventional manual observation are compared. Atlast, beneficial conclusions are given.
出处 《测绘工程》 CSCD 2007年第3期48-51,共4页 Engineering of Surveying and Mapping
关键词 TCA2003全站仪 自动目标识别系统 变形监测 精度分析 TCA2003 total station automatic target recognition (ATR) system deformation monitoring precision analysis