摘要
介绍了分户供暖系统主立管设计位置的一般原则,分析了同程式与异程式供暖系统、户内水平式采暖系统,户内上供下回及户内上供上回采暖系统的优缺点,提出了在分户采暖改造施工中应注意的问题,为室内采暖系统改造提供了参考依据。
The following paper introduces general principle of position design of main riser in household heating system, analyzes the advantages and disadvantages of reversed return and direct return heating system, indoor horizontal heating system, and indoor heating system with upsupply and down-return or up-return, and proposes the problems should be noticed in household heating reconstruction, which to offer a reference for the reconstruction of indoor heating system.
出处
《山西建筑》
2007年第19期188-189,共2页
Shanxi Architecture
关键词
主立管
分户供暖系统
施工
main riser, household heating system, construction