摘要 采用氟离子选择电极法测定氰氨化钙炉料中氟化钙的含量,进行了条件和应用试验。结果表明较佳的条件为:用15mL的盐酸和硼酸混合酸溶解样品,加热时间3min;样品称样量0.5g(准至0.1mg),当w(CaF2)≤1.0%和w(CaF2)=1.0%~2.0%时,测定样品的体积分别为20mL和10mL;先用氢氧化钠溶液将pH值调节至~7,再用乙酸钠调至5~6。在此条件下,测定样品的标准偏差<0.03%,RSD<4%,加标回收率为98%~103%;与EDTA容量滴定法比较,平行误差小、准确度好。该方法可以准确测定出氰氨化钙炉料中氟化钙的含量。 Calcium fluoride content in calcium cyanamide charging is determined by a fluoride ion selective electrode method, and its conditions and applications are tested. Results show that the better conditions are as follows:mixture of 15 mL hydrochloric acid and boric acid is used to dissolve the sample, and heated 3 min; the sample is weighed 0.5 g (precision at 0.1 mg). At w(CaF2)≤1.0% and w(CaF2)=1.0%-2.0%, vol of the sample is determined to be 20 mL and 10 mL, respectively; its pH is adjusted to ~7 with sodium hydroxide solution, followed by sodium acetate to 5-6. Under this condition, standard deviation of the determined sample is<0.03%, RSD<4%, indexed recovery 98%-103%; compared with EDTA precipitation titration method, there are few parallel errors and good in precision. This method can exactly determine calcium fluoride in the calcium cyanamide charging.
出处 《化工生产与技术》 CAS 2007年第3期45-47,共3页 Chemical Production and Technology
关键词 氟化钙 氟离子选择电极法 氰氨化钙 calcium fluoride fluoride ion selective electrode method calcium cyanamide
  • 相关文献

参考文献5

  • 1关瑞宝,刘冬霓,强京林,等.GB603-2002.化学试剂试验方法中所用制剂及制品的制备[M].北京:中国标准出版社,2003.
  • 2齐文启,曾胜年,汪志国,等.水和废水监测分析方法[M].4版.北京:中国环境科学出版社.2006:187-193.
  • 3彭厨治,王国胜.分析化学:第四分册电分析化学[M].2版.北京:化学工业出版社.1999:159—222.
  • 4孙红英,戴凤英,解惠英,等..GB/T1819.15-2006.锡精矿化学分析方法氟量的测定离子选择电极法[M]..北京:中国标准出版社,,2006....
  • 5张穗中,杨艳,曹宏燕.GB 5195.1-2006.萤石氟化钙含量的测定[M].北京:中国标准出版社.2006.

同被引文献23

  • 1陈庆华.离子电极标准加入法测定废水中氟离子抗干扰的探讨[J].上海有色金属,1994,15(1):37-40. 被引量:2
  • 2Calcium Hydroxide //FOOD CHEMICALS CODEX: 5th ed [ S]. Washington, D. C : The National Academies Press. 2004 : p67 - 68.
  • 3Calcium Oxide//FOOD CHEMICALS CODEX: 5th ed[ S]. Washington, D. C : The National Acadenlies Press, 2004 : 72.
  • 4GBT5009.18-2003.食品中氟的测定[S].
  • 5GB/T14506.12-93.硅酸盐岩石化学分析方法:离子选择电极法测定氟量[S].
  • 6Daniel W, Sullivan O', Michael Tyree. The kinetics of complex formation between Ti (IV) and hydrogen peroxide[J]. International Journal of Chemical Kinet- ics, 2007,39(8) :457-461.
  • 7朱瑞芝,解聪敏,吴键,傅学起.离子色谱法直接测定污水中氟离子[A];天津市第六届色谱学术交流会论文集[C];1989.
  • 8马志军,姜鹏威,马正先.阜新沸石用于含氟废水处理的试验研究[A];2008年全国金属矿山难选矿及低品位矿选矿新技术学术研讨与技术成果交流暨设备展示会论文集[C];2008.
  • 9严晔赓.氟离子选择电极法测定废水中氟含量的试验研究[J];电力环境保护;1987.01.
  • 10张占海,田冬.浅谈林业生物质能源新品栎树种籽的开发利用[J].中国林业,2007(11A):52-52. 被引量:1

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部