期刊文献+

6个miniSTR基因座荧光标记复合扩增的遗传多态性 被引量:4

Genetic Polymorphism of 6 MiniSTR Loci Using Fluorescence-labeled Multiplex-PCR Techniques
下载PDF
导出
摘要 目的评价6个miniSTR基因座在DNA高度降解检材中的法医学应用价值,并调查广东汉族人群6个miniSTR基因座的遗传多态性。方法采用两个复合扩增PCR体系、四色荧光标记及毛细管电泳技术,对D1S1677,D2S441,D4S2364,D10S1248,D14S1434,D22S1045基因座进行基因型检测。结果6个miniSTR基因座均获得了清晰的基因型分型结果,扩增片段均小于120bp,分别检出7、7、5、8、8、7个等位基因和14、11、11、19、12、14种基因型,基因型分布均符合Hardy-Weinberg平衡。6个miniSTR基因座在广东汉族群体的个人识别率和非父排除率分别依次为0.863、0.895、0.792、0.894、0.814、0.904和0.392、0.360、0.353、0.568、0.378、0.513。10例IdentifilerTM试剂盒未能正确分型的高度降解DNA样本,采用6个miniSTR基因座复合扩增体系检测均提高了分型成功率结论6个miniSTR基因座荧光标记复合扩增体系在DNA高度降解检材的检测中具有较高的应用价值,并且在广东地区汉族群体中具有较好的遗传多态性。 Objective To evaluate the utility of 6 miniSTR loci (D1S1677, D2S441, D4S2364, D10S1248, D14S1434, and D22S1045) in highly degraded DNA samples, and to investigate the genetic polymorphism in Guangdong Han population. Methods The loci of 6 mini-STR in Han population of Guangdong were genotyped by primers labeled with four-color fluorescent (FAM, HEX, TAMRA and ROX) and two multiplex amplification reaction systems. Results Each locus was successfully genotyped with the product fragment less than 120bp. Among the 216 individuals investigated, 7, 7, 5, 8, 8, and 7 alleles, and 14, 11, 11, 19, 12, and 14 genotypes were detected at D1S1677, D2S441, D4S2364, D10S1248, D14S1434, and D22S1045, respectively. No deviation from Hardy-Weinberg equilibrium was observed in these loci. The discrimination power were 0.863, 0.895, 0.792, 0.894, 0.814, 0.904 and the excluding probability of paternity were 0.392, 0.360, 0.353, 0.568, 0.378, 0.513, respectively. The utility of the 6 miniSTR loci assays was confirmed by a higher successful rate for typing 10 highly degraded DNA samples, which were only partially being typed using Identifiler^TM kit. Conclusion The 6 miniSTR loci show genetic polymorphisms in the Han population of Guangdong. Assays for forensic typing the 6 miniSTR loci appear useful in highly degraded DNA samples.
出处 《法医学杂志》 CAS CSCD 2007年第3期201-205,共5页 Journal of Forensic Medicine
基金 中国博士后科学基金资助项目(2005038506) 广东省自然科学基金资助项目(D6301091)
关键词 MINISTR 复合扩增 遗传多态性 降解DNA miniSTR multiplex PCR genetic polymorphism degraded DNA
  • 相关文献

参考文献16

  • 1Cotton EA,Allsop RF,Guest JL,et al.Validation of the AmpFlSTR SGM Plus^TM system for use in forensic casework[J].Forensic Sci Int,2000,112(2-3):156-161.
  • 2Wallin TM,Buoncristiani MR,Lazaruk KD,et al.TWGDAM validation of the AmpFlSTR SGM Plus(tm) Blue PCR amplification kit for forensic casework analysis[J].J Forensic Sci,1998,48(4):854-870.
  • 3Wiegand P,Kleiber M.Less is more-length reduction of STR amplicons using redesigned primers[J].Int J Legal Med,2001,114(4-5):285-287.
  • 4Tsukada K,Takayanagi K,Asamura H,et al.Multiplex short tandem repeat typing in degraded samples using newly designed primers for the TH01,TPOX,CSFlPO,and vWA loci[J].Legal Med(Tokyo),2002,4(4):239-245.
  • 5Szibor R,Kayser M,Roewer L.Identification of the human Y-chromosomal microsatellite locus DYS19 from degraded DNA[J].Am J Forensic Med Pathol,2000,21(3):252-254.
  • 6Taberlet P,Griffin S,Goossens B,et al.Reliablegenotyping of samples with very low DNA quantitiesusing PCR[J].Nucleic Acids Res,1996,24(16):3189-3194.
  • 7Whitaker JP,Cotton EA,Gill P.A comparison of thecharacteristics of profiles produced with the AmpFl STR SGM Plus multiplex system for both standard and low copy number(LCN)STR DNA analysis[J].Forensic Sci Int,2001,123(2-3):215-223.
  • 8Coble MD,Butler JM.Characterization of new miniSTR loci to aid analysis of degraded DNA[J].J Forensic Sci,2005,50(1):43-53.
  • 9Walsh BS,Petzger DA,Higuchi R.Chelex-100 as medium for simple extraction of DNA for PCR-basedtyping from forensic material[J].Biotechniques,1991,10(4):506-513.
  • 10Brownstein MJ,Carpten JD,Smith JR.Modulation of non-templated nucleotide addition by Taq DNA polymerase:primer modifications that facilitate genotyping[J].Biotechniques,1996,20(6):1004-1006,1008-1010.

二级参考文献26

  • 1[1]Jeffreys M,Wilson V,Thein SL.Hypervariable 'minisatellite' regions in human DNA [J].Nature 1985,314:67-73.
  • 2[2]Butler JM.Forensic DNA typing:biology and technology behind STR markers [M].London:Academic Press,2001.
  • 3[3]Bar W,Kratzer A,Machler M,et al.Postmortem stability of DNA [J].Forensic Sci Int 1988,39 (1):59-70.
  • 4[4]Cotton EA,Allsop RF,Guest JL,et al.Validation of the AmpFISTR SGM PlusTM system foruse in forensic casework [J].Forensic Sci Int 2000,112(2-3):151-61.
  • 5[5]Krenke BE,TerebaA,Anderson SJ,et al.Validation of a 16-locus fluorescent multiplex system [J].J ForensicSci,2002,47 (4):773-85.
  • 6[6]Butler JM,Shen Y,McCord BR.The Development of Reduced Size STR Amplicons as Tools for Analysis of Degraded DNA[J].J Forensic Sci,2003,48(5):1054-1064.
  • 7Whitaker JP,Clayton TM,Urquhart AJ,et al.Short tandem repeat typing of bodies from a mass disaster:high success rate and characteristic amplification patterns in highly degraded samples[J].BioTechniques,1995,18(4):670-677.
  • 8Tsukada K,Takayanagi K,Asamura H,et al.Multiplex short tandem repeat typing in degraded samples using newly designed primers for the TH01,CSF1PO,and vWA loci[J].Legal Medicine,2002,4:239-245.
  • 9Yoshida K,Sekiguchi K,Kasai K,et al.Evaluation of new primers for CSF1PO[J].Int J Legal Med,1997,110(1):36-38.
  • 10Butler JM,Li J,Shaler TA,et al.Reliable genotyping of short tandem repeat loci without an allelic ladder using time-of-flight mass spectrometry[J].Int J Legal Med,1998,112:45-49.

共引文献11

同被引文献56

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部