锅炉高温受热面TP347H管短期开裂分析 被引量:15

Short-time cracking analysis of TP347H tubes of high temperature heat delivery surfaces of boilers
下载PDF
导出
摘要 针对SA213-TP347H钢管材制作的某锅炉过热器管,累计运行不到500 h相继发生弯管内弧周向开裂的事故,用显微金相、元素分析、电子探针、扫描电镜、晶间腐蚀等试验方法进行了失效分析.结果表明:过热器弯管经冷加工后未进行固溶处理,是引发内弧开裂的主要原因.此外,对防止此类事故的发生提出了有益建议. A failure analysis was made on the circumferential cracks of TP347H superheater tubes served in a power plant within 500 hours by means of chemical element analysis, microscopic tests, microscopic metallographic analysis, SEM analysis, EDX analysis and intergranular corrosion tests. The result shows that the main reason for circumferential cracks of the high-temperature superheater elbows is lack of solution treatment. Finally, some useful suggestions for prevention of such failure are proposed.
出处 《武汉大学学报(工学版)》 CAS CSCD 北大核心 2007年第3期80-84,共5页 Engineering Journal of Wuhan University
关键词 过热器管 开裂 晶间腐蚀 固溶处理 high-temperature superheater tubes cracking intergranular corrosion solution heat treatment
  • 相关文献

参考文献6

二级参考文献20

  • 1成海涛,郭元蓉.我国电站锅炉用管的现状与发展对策[J].钢管,2006,35(2):5-9. 被引量:9
  • 2方智,吴荫顺,张琳,李杰.形变诱发马氏体对304不锈钢在活化状态下电化学行为的影响[J].腐蚀科学与防护技术,1997,9(1):75-78. 被引量:25
  • 3徐芝纶.弹性力学(第二版)[M].北京:高等教育出版社,1982..
  • 4陆才善 候德门.钻孔法的三个问题[J].西安交通大学学报,1985,19(3):87-97.
  • 5唐纳德皮克纳 顾守仁等(译).不锈钢手册[M].北京:机械工业出版社,1987..
  • 6印兵胜.盲孔法测量残余应力测试技术[M].郑州机械研究所,2001..
  • 7.E837—81.用钻孔应变测量决定残余应力的标准方法.ASTM标准[S].,..
  • 8.GB3395—92.中华人民共和国船舶行业标准残余应力测量方法,钻孔应变释放法[S].,..
  • 9Soete W and Vancrombrugge, R.An Industrial Method for the Determination of Residual Stresses[J]. Proc SESA Vol8 No 1,1950.
  • 10Michael T, Flaman. Brief Investigation of Induced Drilling Stresses in the Center- Hole Method of Residual- Stress Measurement[J]. Experimental Mechanics, 1982,22( 1 ).