期刊文献+

基于LabView和Matlab混合编程的脑MIT数字鉴相方法的实现 被引量:3

Implementation of digital phase detection in brain MIT based on programming with LabView and Matlab
下载PDF
导出
摘要 目的:为实现用于脑磁感应成像系统中的数字鉴相方法,寻求一种高精度的相位检测手段.方法:本研究采用LabView对数据采集卡编程,控制激励信号的产生和检测信号的采集;采用Matlab进行快速傅立叶变换法(FFT)法,相关法和经典法的编程,用于实现数字鉴相.结果:得到了步进0.1°条件下的数字鉴相结果,构建了一整套包含信号产生、采集和处理的鉴相系统,最终,实现了FFT法和相关法0.1°的相位差分辨率.结论:数字鉴相方法能够应用于脑磁感应断层成像技术(MIT)检测系统中,对高精度的系统测量提供了理论依据. AIM: To realize digital phase detection methods in brain magnetic induction tomography (MIT) system and to find a phase detection method with high accuracy. METHODS: The data acquisition board was programmed with LabView to control the generation of excitation signal and the sampling of detection signal. The fast fourier transform (FFT) method, correlation method and classic method were programmed with Maflab to realize digital phase detection. RFSULTS: The phase detection results with 0.1 o step were obtained and a phase detection system including signal generation, collection and processing was obtained as well. Finally, the FFT method and correlation method reached the phase shift resolution of 0. 1^o. CONCLUSION: Digital phase detection method can be successfully used in the phase shift detection in MIT detection system and provide a theoretical foundation for system measurement.
出处 《第四军医大学学报》 北大核心 2007年第12期1144-1146,共3页 Journal of the Fourth Military Medical University
基金 全军"十一五"课题资助项目(06MA224)
关键词 脑磁感应成像 相位检测 导电性 傅里叶分析 相关法 brain magnetic induction tomography phase detection electric conductivity fourier analysis correlation method
  • 相关文献

参考文献10

  • 1王聪,秦明新,董秀珍,尤富生,李世俊.磁感应方式电导率测量基础研究[J].中国医学物理学杂志,2004,21(3):182-185. 被引量:17
  • 2Rosell J,Merwa R,Brunner P,et al.A multifrequency magnetic induction tomography system using planar gradiometers:Data collection and calibration[ J].Physiol Meas,2006,27:271-281.
  • 3Griffiths H.Magnetic induction tomography Measurement[ J ].Sci Technol,2001,12:1126-1131.
  • 4Watson S,Williams R J,Griffiths H.Frequency downconversion and phase noise in MIT[ J].Physiol Meas,2002,23:189-194.
  • 5Scharfetter H,Casanas R,Rosell J.Biological tissue characterization by magnetic induction spectroscopy (MIS):Requirements and limitations[J].IEEE Trans Biomed Eng,2003,50:870-880.
  • 6清华大学电机系虚拟仪器实验室,北京中科泛华测控技术有限公司编译LabView用户指南(LabView User Manual January 1998Edition)[M].北京:2000,28:1-7.
  • 7郑南宁.数字信号处理[M].西安:西安交通大学出版社,1997:133-179.
  • 8曹宇亚,申忠如,任稳柱.介质损耗带电检测数字化处理方法的研究[J].高压电器,2000,36(3):17-19. 被引量:36
  • 9李世俊,秦明新,董秀珍,尤富生,史学涛,付峰.非接触磁感应脑阻抗断层成像系统设计[J].中国医学物理学杂志,2003,20(1):55-58. 被引量:21
  • 10秦明新,李世俊,董秀珍,等.非接触磁感应脑电导率断层成像系统实验系统研究[A].见:中国科协2003年学术年会文集[C].北京:中国科学技术出版社.2003:314.

二级参考文献8

  • 1Johannes Netz, Ewald Fornert, Sabine Elaagemannf. Contactless impedance measurement by magnetic induction-a possible method for investigation of brain impedance[J]. Physiol. Meas., 1993,14:463~471.
  • 2Griffiths H, Stewart WR, Gough W. Magnetic induction tomography-A measuring system for biological tissues[J]. Ann N Y Acad Sci., 1999,873:335~345.
  • 3Griffiths H. Magnetic induction tomography [J]. measurement science and technology, 2001,12:1126~1131.
  • 4Morris A, Griffiths H, Gough W. A numerical model for magnetic induction tomographic measurements in biological tissues[J]. Physiol. Meas., 2001,22:113~119.
  • 5S Watsonl, R J Williams, H Griffiths, W Gough, A Morris. Magnetic induction tomography: phase versus vector-voltmeter measurement techniques[J]. Physiol. Meas., 2003,24:555~564.
  • 6董秀珍,秦明新,刘锐岗,汤孟兴,史学涛,尤富生,付峰.影响生物电阻抗断层成像质量的因素[J].中国医学物理学杂志,2001,18(4):206-207. 被引量:9
  • 7李世俊,秦明新,董秀珍,尤富生,史学涛,付峰.非接触磁感应脑阻抗断层成像系统设计[J].中国医学物理学杂志,2003,20(1):55-58. 被引量:21
  • 8李世俊,秦明新,董秀珍,尤富生,史学涛,付峰,刘锐岗,李江.非接触磁感应脑阻抗断层成像系统激励源设计[J].第四军医大学学报,2003,24(2):176-178. 被引量:10

共引文献68

同被引文献20

  • 1胡晓彦,秦明新,焦明克,梁文文,张华.磁感应成像系统中相位检测方法研究[J].医疗卫生装备,2007,28(4):11-13. 被引量:8
  • 2QIN Mingxin, JIAO Licheng, LI Shijun, et al. A single channel system for brain MIT [ J]. Chinese J Biomed Eng, 2004, 13(9): 47-54.
  • 3Qin Ming-xin,Jiao Li-eheng,Li Shi-jun,et d. A single channel sys- tem for brain MIT[J]. Chinese J Biomed Eng, 2004,13 ( 9 ) : 47-54.
  • 4路艳洁,席志红,王姜铂.FFT法与数字相关法在相位测量上的比较[J].信息技术,2007,31(12):105-108. 被引量:36
  • 5Taudorf S, Berg RM, Bailey DM, et al. Cerebral blood flow and oxygen metabolism measured with the Kety-Schmidt method using nitrous oxide[J]. Acta Anaesthesiol Scand, 2009, 53(2): 159-167.
  • 6Obrist W, Wilkinson W. Regional CBF measurement in humans by xenon-133 clearance [J]. Cerebrovasc Brain Metab Rev, 1990, 2(4):283-327.
  • 7Sundt Jr TM, Sharbrough FW, Anderson RE, et al. Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy[J]. J Neurosurg, 2007, 107(4): 885-886.
  • 8Jin G, Sun J, Qin MX. A special phase detector for magnetic inductive measurement of cerebral hemorrhage[J]. PLOS ONE, 2014, 9(5): 1-7.
  • 9Mahdavi H, Rosell-Ferrer J. Magnetic induction-based sensor for vital sign detection[J], IFMBE Pro, 2014, 41: 1507-1510.
  • 10韩珂,邢英琦,李兴志.经颅多普勒超声的临床应用与进展[J].中风与神经疾病杂志,2008,25(1):116-119. 被引量:4

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部