静电除尘器常见故障原因分析及对策 被引量:1

Analysis of Causes for Common Failure of Electrostatic Precipitator and Countermeasures
下载PDF
导出
摘要 简单介绍了静电除尘器工作原理及基本结构。对静电除尘器的常见故障,即负载短路、保温箱电加热器损坏、除尘效率降低及二次电压高、二次电流低进行原因分析,提出了处理对策及预防措施。 A brief account is given of the working principle and basic structure of the electrostatic precipitator. An analysis is made of the causes for its common failure, viz. , load short circuiting, damage of electric heater of insulation can, low dust collecting efficiency, high secondary voltage, and low and fluctuating secondary current, and countermeasures and preventive measures are put forward.
作者 李敬珂
出处 《化肥工业》 CAS 2007年第3期48-50,共3页 Chemical Fertilizer Industry
关键词 静电除尘器 故障原因 对策 预防措施 electrostatic precipitator causes for failure countermeasures preventive measures