脉冲激光测距系统中高精度时间间隔测量模块的研究 被引量:43

STUDY ON HIGH RESOLUTION TIME INTERVAL MEASUREMENT MODULE IN PULSED LASER RANGING SYSTEM
下载PDF
导出
摘要 时间间隔的测量精度对脉冲激光测距系统的测量精度起决定作用.为此研制了一高精度时间间隔测量模块,该模块基于专用时间数字转换芯片开发,采用延迟线插入法技术,最大测量时间可高达200m s,测时分辨率最高可达125ps,对应测距分辨率18.75mm,适用于远距离的测量.给出了硬件和软件设计方法以及模块的测试结果. The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement. Therefore, a high resolution time interval measurement module was developed. The module is based on the special time-to-digital conversion chip which adopts the delay line interpolation method. The maximum measuring time of the module is 200ms, and the maximum time resolution is 125ps, of which the corresponding distance resolution is 18.75mm. The module is especially suit for the large distance measurement. The hardware and the software of the module as well as the testing results are also presented.
出处 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2007年第3期213-216,221,共5页 Journal of Infrared and Millimeter Waves
基金 中国科学院创新三期项目(11100404K221JW19)
关键词 脉冲激光测距 时间间隔测量 时间数字转换 延迟线插入法 pulsed laser ranging time interval measurement time-to-digital conversion delay line interpolation method
  • 相关文献

参考文献7

二级参考文献29

  • 1陈育伟,张立,胡以华,张海洪,舒嵘,王建宇.对地观测激光成像的回波阵列探测技术[J].红外与毫米波学报,2004,23(3):169-171. 被引量:19
  • 2Dennis L.McCormak.Electro-optical detector laser susceptibility testing[ C ].Proc.SPIE,1989,1050:137-146.
  • 3[1]K M??tt? and J Kostamovaara.A high- precis ion time-to-digital converter for pulsed time-to-flight laser radar applicat ions[J].IEEE Trans,Instr.and Meas.,1998,47(2):521~536.
  • 4[2]R Ahola and R Myllyl.A new method for measuring the t ime-of-flight in fast laser range finding[J].Proc.SPIE,1986,654:19~25.
  • 5[3]G S Gao, R Partridge.High speed digital TDC for D0 vertex reconstruction[J].IEEE Trans.Nucl.Sci.,1991,38(2):286~289.
  • 6[4]R Nutt.Digital time intervalometer[J].Rev.Sci.Instr.,1968,3 9(3):1342~1345.
  • 7[5]J Kalisz.Single-chip interpolating time counter with 200-ps reso lution and 43-s range[J].IEEE Trans.Instr.and Meas.,1997,46(4):851~856.
  • 8[6]Timo E Rahkonen, J Kostamovaara.The use of stabilized CMOS dela y lines for the digitization of short time intervals[J].IEEE J.of Solid-State Circuits,1993,28(8):887~894.
  • 9[7]E R?is?nen-Ruotsalainen,Timo Rahkonen,J Kosta mova ara,A low-power CMOS time-to-digital converter[J].IEEE J.of Solid-State Ci rcuits,1995,30(9):984~990.
  • 10[8]B Turko.A picosecond resolution time digitizer for laser rang ing[J].IEEE Trans.Nucl.Sci.,1978,NS-25:75~80.

共引文献112

同被引文献210

引证文献43

二级引证文献321

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部