摘要 将带整流负载的同步发电机的d、q轴变量分解为低频分量和高频分量,并分别加以处理。转子回路对高频电流的电阻及阻尼绕组对低频分量的作用可以忽略。在d轴与q轴超瞬变电抗值相差不大的条件下,建立了带整流负载的三相同步发电机的等效电路模型,该模型可用于同步发电机整流系统稳态和似稳态过程的分析计算。给出了系统稳态运行时等效同步发电机的相量图及稳态量的计算方法。 The d and q axis variables of a rectifier loaded synchhronous generator are resolved into low frequency and high frequency components, which can be treated separately. The resistances of the rotor circuits to high frequency currents and the effects of the damper windings on low frequency components need not be taken into account. An equivalent circuit model of the rectifier loaded 3 phase synchronous generator with d axis subtransient reactance x ″ d equal to q axis subtransient reactance x ″ q is developed for steady state and quasi steady state analysis of the synchronous rectifier load system. The phasor diagram of the equivalent synchronous generator and the method of performance calculations are presented for steady state operation.
出处 《清华大学学报(自然科学版)》 EI CAS CSCD 北大核心 1997年第4期97-100,共4页 Journal of Tsinghua University(Science and Technology)
关键词 同步发电机 整流器 电路模型 稳态过程 synchronous generators rectifiers circuit models
  • 相关文献

参考文献1

  • 1张晓锋,Proceedings of IMECE’94,1994年

同被引文献59

  • 1李庆民,王冠,李清泉.电力系统相控开关技术及其智能控制策略[J].电气开关,2004,42(3):42-46. 被引量:39
  • 2孙俊忠,姜海龙.3/12相双绕组交直流发电机的电路模型[J].电机与控制应用,2006,33(2):12-16. 被引量:6
  • 3马伟明,张盖凡.三相同步发电机供交直流混合负载时交流电压波形的畸变[J].电工技术学报,1996,11(4):36-42. 被引量:12
  • 4刘念,谢驰,王涛,陈实,孙克金,周步祥,冉立.基于免疫算法的无刷励磁发电机旋转整流器故障诊断[J].电力自动化设备,2007,27(5):32-35. 被引量:17
  • 5[1]Franklin P W.A theoretical study of the three phase salient pole type generator with simultaneous AC and bridge rectified DC output-part I and part II [J].IEEE Transactions on Power Apparatus and Systems, 1973,92(2):543-557.
  • 6[3]Schiferl R F,Ong C M.Six phase synchronous machine with AC and DC stator connections,Part I and Part II [J].IEEE Transactions on Power Apparatus and Systems,1983,102(8):2685-2701.
  • 7[6]Ma Weiming,Hu An,Liu Dezhi,et al.Stability of a synchronous generator with diode-bridge rectifier and back-EMF load [J].IEEE Transactions on Energy Conversion,2000,15(4):458-463.
  • 8Yang Qing, Ma Weiming, Sun Junzhong, et al.Stability analysis of a synchronous generator with simultaneous A C and rectified D C load.Proceedings of ICEMS' 2001,Shenyang China, 2001:587--591.
  • 9Shimizu H, Yokomizu Y, Goto M et al. A study on required volume of superconducting element for flux flow resistance type fault current limiter[J]. IEEE Transactions on Applied Superconductivity, 2003,13(2): 2052-2055.
  • 10Mukhopadhyay S C, Dawson F P, Iwahara M et al. A novel compact magnetic current limiter for three phase applications[J]. IEEE Trans.onMagnetics, 2000, 36(5): 3568-3570.