期刊文献+

Calculating magnetic shielding effectiveness for high-power dc comparator by magnetic circuit method

Calculating magnetic shielding effectiveness for high-power dc comparator by magnetic circuit method
下载PDF
导出
摘要 Magnetic shielding is very important in the design of a high-power dc comparator. This paper addressed the application of magnetic circuit method to calculate the magnetic shielding effectiveness of high-power dc comparators when an external radial magnetic field is added. The mathematical relationship between the magnetic shielding effectiveness and the parameters of the magnetic shielding body were obtained. To verify the validity of the calculation method, we developped a procedure to measure the magnetic shielding effectiveness of the magnetic body by measuring the induction voltage of the detection winding instead of the magnetic intensity at a point in the magnetic shielding body, making the manipulation much easier. The result calculated with the magnetic circuit method turns out to be closer to the measured one compared with that calculated with a conventional algorithm proposed by Ren, suggesting that the magnetic circuit method is an applicable tool for estimating the toroidal cavity magnetic shielding effectiveness of a heavy current comparator when a radial magnetic field is added. Magnetic shielding is very important in the design of a high-power dc comparator. This paper addressed the application of magnetic circuit method to calculate the magnetic shielding effectiveness of high-power dc comparators when an external radial magnetic field is added. The mathematical relationship between the magnetic shielding effectiveness and the parameters of the magnetic shielding body were obtained. To verify the validity of the calculation method, we developped a procedure to measure the magnetic shielding effectiveness of the magnetic body by measuring the induction voltage of the detection winding instead of the magnetic intensity at a point in the magnetic shielding body, making the manipulation much easier. The result calculated with the magnetic circuit method turns out to be closer to the measured one compared with that calculated with a conventional algorithm proposed by Ren, suggesting that the magnetic circuit method is an applicable tool for estimating the toroidal cavity magnetic shielding effectiveness of a heavy current comparator when a radial magnetic field is added.
出处 《Journal of Chongqing University》 CAS 2007年第2期113-118,共6页 重庆大学学报(英文版)
基金 Funded by the Natural Science Foundation of China under the grant number 50277018.
  • 相关文献

参考文献6

  • 1Ren SY.A 100 000 A high precision on-site measurement calibration device for heavy direct current[].IEEE Transactions on Instrumentation and Measurement.1990
  • 2Ren SY,Ding HC.A 300 000 A high precision dc comparator for on-line calibration and measurement[].IEEE Transactions on Instrumentation and Measurement.1991
  • 3Ren SY,Ding HC,Li MM,et al.Magnetic shielding effectiveness for comparator[].IEEE Transactions on Instrumentation and Measurement.1995
  • 4Wang DH,Zhao JS.The principle and device of electromagnetism compatible[]..1995
  • 5Moore WJM,Miljanic PN.The current comparator[]..1988
  • 6Lv RQ,Jiang QX.Electric and magnetic compatibility structure design[]..1990

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部