期刊文献+

基于互信息的多模态医学图像配准技术研究 被引量:3

Research on Multi-Modality Medical Image Registration Based on Mutual Information
下载PDF
导出
摘要 分析了互信息配准的物理基础和配准原理,提出了利用差图像熵的互信息测度,对多种具有代表性的互信息测度进行了比较,并用邻域信息对差图像互信息进行了改进。试验结果表明,与空域信息相结合的互信息测度具有更好的抗噪性。 After analyzing the principle of registration based on MI, it presents an adaptation of MI by using the entropy of different image and comparing several kinds of similarity measure. Results show that the combined MI with spatial information has better anti-interference.
作者 胡永祥 蒋鸿
出处 《湖南工业大学学报》 2007年第3期56-60,共5页 Journal of Hunan University of Technology
关键词 互信息 多模态图像 医学图像配准 相似性测度 mutual information multi-modality image medical image registration similarity measure
  • 相关文献

参考文献6

  • 1[1]Viola P,Wells W.Alignment by maximization of mutual information[C]//In:Proceedings of the 5th International Conference on Computer Vision.Boston:MA,1995:16-23.
  • 2[2]Collignon A,Maes F,Vandermeulen D,et al.Automated multimodality image registration using information theory[C]//In:Proceedings of the Information Processing in Medical Imaging Conference.Dordrecht:Kluwer Academic Publishers,1995:263-274.
  • 3[3]Pluim J P W,Maintz J B A,Viergever M A.Image registration by maximization of combined mutual information and gradient information[J].IEEE Trans.Med,Imaging,2000,19(8):809-814.
  • 4[4]Russakoff D B,Tomasi C,Rohl-ng T C R,Maurer J.Image similarity using mutual information of regions[C]//In:Proceedings of the 8th European Conference on Computer Vision(ECCV).Prague:Springer,2004:596-607.
  • 5[6]Woods R P,Mazziotta J C,Cherry S R.MRI-PET registration with automated algorithm[J].Journal of Computer Assisted Tomography,1993,17(4):536-546.
  • 6[7]Studholme C,Hill D L G,Hawkes D J.An overlap invariant entropy measures of 3D medical image alignment[J].Pattern Recognition,1999,32(1):71-86.

同被引文献37

引证文献3