摘要 介绍了用气相色谱法检测毒死蜱农药在桂皮中的残留方法,选用Agilent 6890N气相色谱仪,DB-1701和HP-5双柱法、火焰光度检测器(FPD)和电子俘获检测器(ECD)双检测器来定性,外标法定量,并采用中性氧化铝柱净化样液,效果良好,节约检测成本,回收率为86.7%~93.4%,各项指标均满足有关要求. The residue analytical method for chlorpyrifos pesticides in cassia by GC was introduced. The Agilent 6890N gas chromatograph was used with DB-1701 and HP-5 capillary column,flame photometric detector(FPD) and electron capture detector (ECD), using external standard method. The pesticides were cleaned--up with alumina neutral to get the good effect and save examination cost, The average recovery was 86.7%-93.4%, All the technical items conformed to the requirements.
作者 李达 蔡璇
出处 《分析测试技术与仪器》 CAS 2007年第2期145-147,共3页 Analysis and Testing Technology and Instruments
关键词 气相色谱 农药残留 桂皮 双检测器 GC pesticide residues cassia double detector