DSA图像质量控制 被引量:10

Quality Control of DSA Image
下载PDF
导出
摘要 合理利用了某些机械设备,同时运用了DSA技术,探讨DSA图像质量的控制直接影响临床的诊断与治疗。通过对数字减影血管造影图像质量分析及各项技术要素优化,使得DSA图像质量得以控制,保证临床诊断、治疗的准确性。对医疗科研、新技术提供可靠的依据。 Utilizes some equipment properly and makes a good use of DSA technology, discusses the quality control of DSA image influences directly on clinical diagnosis and treatment. Through analysis on the image quality of digital DSA angiographies and optimization of each technical essential factor, the quality of DSA image can be controlled to ensure the accuracy of clinical diagnosis and treatment, and provide the reliable basis for the development of new technique and scientific research of medical treatment.
作者 董斌 李新煜
出处 《医疗设备信息》 2007年第6期81-83,7,共4页 Information of Medical Equipment
关键词 DSA 图像 质量控制 DSA image quality control
  • 相关文献

参考文献5

  • 1高凯,孙立军,邓振生,牟轩沁,余厚军,张学昕.X线图像质量与造影剂浓度和放射剂量相关性研究[J].实用放射学杂志,2005,21(1):1-4. 被引量:12
  • 2Marx MV.The radiation dose in interventional radiology study:knowledge brings responsibiligy[J].J Vasc Interv Radiol,2003,14(8):947-951.
  • 3Vetter S,Schultz FW,Strecker EP,et al.Patient radiation exposure in uterine artery embolization of leiomyomata:calculation of organ doses and effective dose[J].Eur Radiol,2004,14(2):842-848.
  • 4Bor D,Sancak T,Olgar T,et al.Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology[J].Br J Radiol,2004,77(4):315-322.
  • 5Gkanatsios NA,Huda W,Peters KR.Adult patient doses in interventional neuroradilogy[J].Med Phys,2002,29(5):717-723.

二级参考文献9

  • 1Marx MV. The radiation dose in interventional radiology study: knowledge brings responsibiligy[J].J Vasc Interv Radiol, 2003, 14(8 ):947-951.
  • 2Vetter S, Schultz FW, Strecker EP, et al. Patient radiation exposure in uterine artery embolization of leiomyomata: calculation of organ doses and effective dose[J].Eur Radiol,2004, 14(2):842-848.
  • 3Bor D, Sancak T, Olgar T, et al. Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology[J].Br J Radiol,2004, 77(4 ):315-322.
  • 4Gkanatsios NA, Huda W, Peters KR. Adult patient doses in interventional neuroradilogy[J].Med Phys,2002, 29(5):717-723.
  • 5Vano E, Goicolea J, Galvan C, et al. Skin radiation injuries in patients following repeated coronary angioplasty procedures[J].Br J Radiol,2001, 74(11 ):1023-1031.
  • 6Onnasch DGW, Schemm A, Kramer HH. Optimization of radiographic parameters for paediatric cardiac angiography[J].Br J Radiol,2004, 77(6): 479-487.
  • 7Kemerink GJ, de Haan MW, Vasbinder GBC, et al. The effect of equipment set up on patient radiation dose in conventional and CT angiography of the renal arteries[J].Br J Radiol,2003, 76(9): 625-630.
  • 8Gkanatsios NA. Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography[J].Med Phys,2002, 29(8):1643-1650.
  • 9Prasad KN, Cole WC, Haase GM. Radiation protection in humans: extending the concept of as low as reasonably achievable (ALARA) from dose to biological damage[J].Br J Radiol,2004, 77(2): 97-99.

共引文献11

同被引文献59

引证文献10

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部