以石岘造纸厂不同时期引进的新闻纸纸机为例,从气流组积和维护结构的保温方面分析了冬季北方寒冷地区造纸车间防止结露的措施。
The problems and the solutions of paper machine room ventilation of the project(1989) of Shixian paper mill are introduced, the current situation of paper machine room ventilation of the project(2001) of the mill and the reasons of good ventilation of the paper machine room are summarized. The protection structures and ventilation methods required for preventing condensing in a large newsprint machine room in the northern cold area are discussed in detail.