Carebolus与testbolus两种测试方法在磁共振CE-MRA中的应用比较 被引量:8

The comparative study of carebolus and testbolus in contrast-enhanced magnetic resonance angiography
下载PDF
导出
摘要 目的比较Carebolus与testbolus两种测试方法在CEMRA中的有效性。方法搜集行CE-MRA的病例64例,其中头颈部26例,胸腹部18例,四肢20例。均在行CE-MRA前先进行Carebolus(51例)或testbolus(13例)测试。结果用Carebolus测试的有5例显示不满意;用testbolus测试的有1例不满意。其余CE-MRA效果均满意。结论Carebolus与testbolus两种测试方法各有优缺点,临床上应根据不同的成像血管和不同的血流动力学特点进行选择。 Objective To evaluate the effectiveness of carebolus and testbolus in contrast-enhanced magnetic resonance angiography (CE-MRA), Methods CE-MRA were performed in sixty-four patients, including 26 CE-MRA of head-neck, 18 CE-MRA of thorax-abdomen and 20 CE-MRA of limbs, Either t carebolus or testbolus was performed before contrast-enhancement magnetic resonance angiography, Results High quality images were displayed except five cases with carebolus test and one case with testbolus test. Conclusion Optimal imaging protocol of test method in contrast-enhanced magnetic resonance angiography should be selected according to the target vessels and its characteristics,
出处 《影像诊断与介入放射学》 2007年第3期106-108,共3页 Diagnostic Imaging & Interventional Radiology
关键词 磁共振血管造影 对比增强 测试 评价研究 Magnetic resonance angiography, Contrast enhancement Test Evaluation study
  • 相关文献

参考文献4

二级参考文献27

  • 1Earls JP, Rofsky NM, DeCorato DR, et al. Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector. Radiology, 1996, 201:705
  • 2Foo TK, Saranathan M, Prince MR, et al. Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional,gadolinium-enhanced MR angiography. Radiology, 1997, 203: 275
  • 3Prince MR, Narasimham DL, Stanley JC, et al. Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. Radiology, 1995, 197:785
  • 4Maki JH, Prince MR, Londy FJ, et al. The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality. J Magn Reson Imaging, 1996, 6:642
  • 5Riederer SJ, Bernstein MA, Breen JF, et al. Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering:design specifications and technical reliability in 330 patient studies. Radiology, 2000, 215:584
  • 6Lee JJ, Tirman PJ, Chang Y, et al. The pptimization of scan timing for contrast-enhanced magnetic resonance angiography. Korean Journal of Radiology, 2000, 1:142
  • 7Wikstrom J, Johansson L, Karacagil S, et al. The importance of adjusting for differences in proximal and distal contrast bolus arrival times in contrast-enhanced iliac artery magnetic resonance angiography. Eur Radiol, 2003, 13:957
  • 8Maki JH,Prince MR,Londy FJ,et al.The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality.J Magn Reson Imaging,1996,6:642-651.
  • 9Riederer SJ,Bernstein MA,Breen JF,et al.Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering:design specifications and technical reliability in 330 patient studies.Radiology,2000,215:584-593.
  • 10Lee JJ,Tirman PJ,Chang Y,et al.The optimization of scan timing for contrast-enhanced magnetic resonance angiography.Korean J Radiol,2000,1:142-151.

共引文献19

同被引文献58

引证文献8

二级引证文献32

相关作者