摘要 本文对直流比较仪比例误差的测量问题进行了探讨和分析,介绍了4种测量方法及误差理论分析,结果表明换位式电压比对法适用于测量精度低于1×10^(-5)的直流匝比仪器,电流对按法适用于测量精度低于1×10^(-6)的直流匝比仪器。而小电流测差法、调制电压法适用于测量精度低于1×10^(-7)的直流比较仪,其中调制电压法是一种很有应用前景的测量方法。 In this paper, measurement of ratio-error of DC comparator is discussed. Four kinds of measurement method and their theoretical analysis for error are introduced. The analysis shows that changing-pasition voltage comparison is used to calibrate ratio-error of these DC instruments whose accuracy is less than 1 × 10^(-5), carrent—compareing method is used to calibrate ratio-error of those DC instruments whose accurary is less than 1×10^(-6). However, differences of currents-compareing method and modulatead voltage method areu sed to calibrate ratio error of DC instruments whose accuracy is less than 1 × 10^(-7), where modulated voltage will be widely used in the future as a measurement method.
出处 《高电压技术》 EI CAS CSCD 北大核心 1990年第4期31-36,共6页 High Voltage Engineering
  • 相关文献

同被引文献10

  • 1王瑞峰,米根锁.霍尔传感器在直流电流检测中的应用[J].仪器仪表学报,2006,27(z1):312-313. 被引量:31
  • 2瞿清昌.磁性材料测量[M].北京:中国计量科学研究院,1990,4.
  • 3松井邦彦.传感器应用技巧141例[M].北京:科学出版社,2006.
  • 4冈村廸夫.OP放大电路设计[M].王玲,徐雅珍,李武平,译.北京:科学出版社.2004:80-100.
  • 5MANIKTALA S.Switch power supplies A to Z[M].北京:人民邮电出版社,2011:120-123.
  • 6远坂俊昭.测量电子电路设计-滤波器篇[M].北京:科学出版社,2004:79-81.
  • 7COLONEL W.变压器与互感器设计手册[M].北京:中国电力出版社,2011:32-34.
  • 8邵海明,李之彬,王宝君,等.直流高压电源纹波测量装置[C]∥桂林:第四届全国电磁计量大会文集,2007:89-92.
  • 9王一丽,朱剑平,江习,等.直流电源纹波和噪声测量方法[C]∥桂林:第四届全国电磁计量大会文集,2007:96-97.
  • 10同金,马煜峰.直流电源输出的纹波和噪声的测量[J].电子测试,2010,21(2):88-91. 被引量:25