期刊文献+

Optimal operation of water distribution networks under local pipe failures 被引量:3

Optimal operation of water distribution networks under local pipe failures
下载PDF
导出
摘要 The optimal operation of water distribution networks under local pipe failures, such as water main breaks, was proposed. Based on a hydraulic analysis and a simulation of water distribution networks, a macroscopic model for a network under a local pipe failure was established by the statistical regression. After the operation objectives under a local pipe failure were determined, the optimal operation model was developed and solved by the genetic algorithm. The program was developed and examined by a city distribution network. The optimal operation alternative shows that the electricity cost is saved approximately 11%, the income of the water corporation is increased approximately 5%, and the pressure in the water distribution network is distributed evenly to ensure the network safe operation. Therefore, the proposed method for optimal operation under local pipe failure is feasible and cost-effective. The optimal operation of water distribution networks under local pipe failures, such as water main breaks, was proposed. Based on a hydraulic analysis and a simulation of water distribution networks, a macroscopic model for a network under a local pipe failure was established by the statistical regression. After the operation objectives under a local pipe failure were determined, the optimal operation model was developed and solved by the genetic algorithm. The program was developed and examined by a city distribution network. The optimal operation alternative shows that the electricity cost is saved approximately 11%, the income of the water corporation is increased approximately 5%, and the pressure in the water distribution network is distributed evenly to ensure the network safe operation. Therefore, the proposed method for optimal operation under local pipe failure is feasible and cost-effective.
出处 《Journal of Central South University of Technology》 EI 2007年第3期436-441,共6页 中南工业大学学报(英文版)
基金 Project(50278062) supported by the National Natural Science Foundation of China Project(003611611)supported by the Natural Science Foundation of Tianjin, China
关键词 水分布网络 局部管道故障 巨观模型 最佳运转 water distribution network local pipe failure macroscopic model optimal operation
  • 相关文献

参考文献2

二级参考文献6

  • 1SMITH L A.Option for Leak and Break detection and Repair for Drink Water Systems.Battelle Press,2000.
  • 2PELLETIER G,MAILHOT A,VILLENEUVE J P.Modeling Water Pipe Breaks-Three Case Studies,Water Resources Planning and Management,2003(3/4):115-123.
  • 3KLEINER Y,RAJANI B.Comprehensive review of structural deterioration of water mains:statistical models,Urban Water,2001(3):151-164.
  • 4RAJANI B,KIEINER Y.Comprehensive review of structural deterioration of water mains:physically based models,Urban Water,2001(3):177-190.
  • 5LASEY K,MAYS L W,TUNG Y K.Relibility and availability analysis of water distribution systems,Water Distribution System Management Handbook.
  • 6Liggett J A,J Hydraul Eng ASCE,1994年,120卷,934页