安全稳定控制系统切负荷量分配算法 被引量:12

Distributing algorithm of load-shedding for security and stability control system
下载PDF
导出
摘要 目前安全稳定控制系统在电网中已得到了广泛的应用。在电网发生严重故障后,安全稳定控制系统将根据策略确定须切负荷总量。如何将切除总量合理地分配至各执行站,需制定一套行之有效、兼顾全面的算法。首先确定了算法所应满足的五项基本原则,然后相应地介绍了两种算法。其中,轮次法在满足各项基本原则的前提下,通过全局逼近的方法,大幅减少了安全稳定控制系统的过切量,有效降低了事故情况下系统和用户的损失。轮次法在实际应用中的效果显著。 Today security and stability control system has been applied to the power grid widely. After serious fault appears, security and stability control system will decide the quantity of load-shedding according to the decision table. An effective full-scale algorithm is needed to distribute it to each actuating station. Firstly, five basic principles are established. Then, two algorithms are introduced. The algorithm based on priority can cut down the quantity of load-shedding greatly and reduce the loss of system and user effectivelv. Its application is remarkable.
出处 《继电器》 CSCD 北大核心 2007年第11期26-29,共4页 Relay
关键词 安全稳定控制 控制策略 切负荷 轮次 权重 security and stability control control strategy load shedding sequence weight
  • 相关文献

参考文献9

二级参考文献42

  • 1孙光辉,沈国荣.加强三道防线建设 确保电网的安全稳定运行[J].江苏电机工程,2004,23(5):4-7. 被引量:22
  • 2孙光辉.电力系统稳定控制装置的模块化结构.第六届全国继电保护学术研讨会论文集[M].深圳,1996..
  • 3电力部电力系统安全稳定控制调查组,电力系统自动化,1998年,22卷,9期
  • 4孙光辉,第六届全国继电保护学术研讨会论文集,1996年
  • 5袁季修,电力系统安全稳定控制,1996年
  • 6Xue Y,Int Sympo Power Systems,1993年
  • 7U.S.-Canada Power system outage task force. Final report [EB/OL]. https://reports.energy.gov/, March 31, 2003.
  • 8Bush R. The blackout: from speculation & opportunism to reality[J]. Transmission&Distribution, 2004, 56(5): 6.
  • 9Spectral Lines. The unruly grid: one year latter[J]. IEEE Spectrum, 2004, 41(8)(TNT): 5.
  • 10Pereira L. Cascade to black[J]. IEEE Power & Energy Magazine,2004, 2(3): 54-57.